DORAVILLE, GA ·
OSHA Inspection: BELTMANN RELOCATION GROUP
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BELTMANN RELOCATION GROUP in 7030 BUFORD HIGHWAY, DORAVILLE, GA 30340 (NAICS 484110). OSHA activity number 339245300.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BELTMANN RELOCATION GROUP
- Site address
- 7030 BUFORD HIGHWAY
- City
- DORAVILLE
- State
- GA
- ZIP
- 30340
- Mailing
- 7030 BUFORD HIGHWAY, DORAVILLE, GA 30340
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 484110
- Employees
- 23
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.22 B01
- Issued
- Aug 29, 2013
- Abate by
- Sep 9, 2013
- Penalty
- Initial $6,000 · Current $3,750 Reduced
General-duty citation text
29 CFR 1910.22(b)(1): Where mechanical handling equipment was used, aisles and passageways were not kept clear and in good repair, with no obstruction across or in aisles that could create a hazard. On or about 8/1/13 in the warehouse storage area of the facility; The employees operating powered industrial trucks in the warehouse aisles and employee passageways area were obstructed by household goods, crates, and other material creating a struck-by hazard.
Recent events (2)
- · I (S) $3750
- · Z (S) $6000
1910.22 B02
- Issued
- Aug 29, 2013
- Abate by
- Sep 30, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(b)(2): Permanent aisles and passageways were not appropriately marked: On or about 8/1/13 in the warehouse storage area of the facility; The employees are exposed to a struck-by hazard from the powered industrial trucks being operated in the aisles and passageways that were not marked.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.36 D01
- Issued
- Aug 29, 2013
- Abate by
- Sep 30, 2013
- Penalty
- Initial $6,000 · Current $3,750 Reduced
General-duty citation text
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge: On or about 8/1/13 in the warehouse storage area of the facility; The exit doors in the receiving, shipping, and rear of the warehouse area were locked with deadbolts which prevented the employees from exiting the building safely in case of an emergency.
Recent events (2)
- · I (S) $3750
- · Z (S) $6000
1910.37 A03
- Issued
- Aug 29, 2013
- Abate by
- Sep 9, 2013
- Penalty
- Initial $6,000 · Current $3,750 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: On or about 8/1/13 in the warehouse storage area of the facility; The exit doors in the front and rear of the warehouse areas were obstructed by household goods, wooden crates, and other material preventing the employees from exiting the building safely in case of an emergency or fire.
Recent events (2)
- · I (S) $3750
- · Z (S) $6000
1910.37 A04
- Issued
- Aug 29, 2013
- Abate by
- Sep 9, 2013
- Penalty
- Initial $6,000 · Current $3,750 Reduced
General-duty citation text
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times: On or about 8/1/13 in the warehouse storage area of the facility; Employees working in the warehouse area are exposed to an entrapment and trip hazard where the emergency exit lights at the exit doors were not functioning which prevented them from exiting the building safely.
Recent events (2)
- · I (S) $3750
- · Z (S) $6000
1910.147 C01
- Issued
- Aug 29, 2013
- Abate by
- Sep 25, 2013
- Penalty
- Initial $7,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: On or about 8/1/13 in the warehouse storage area of the facility; An energy control program with specific energy control procedures were not developed where employees were performing repairs and troubleshoot the powered industrial truck.
Recent events (2)
- · I (S) $0
- · Z (S) $7000
1910.178 P01
- Issued
- Aug 29, 2013
- Abate by
- Sep 9, 2013
- Penalty
- Initial $3,000 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s): On or about 8/1/13 in the warehouse storage area of the facility; Where powered industrial trucks were not functional for electrical defects the employer failed identify and take the equipment out of service by tagging them unsafe for operation.
Recent events (2)
- · I (S) $2000
- · Z (S) $3000
More inspections in this industry (NAICS 484110)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339245300.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.