WEST CHESTER, PA —
OSHA Inspection: O'ROURKE & SONS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of O'ROURKE & SONS, INC. in 992 S. BOLMAR ST., WEST CHESTER, PA 19382 (NAICS 332312). OSHA activity number 339246613.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- O'ROURKE & SONS, INC.
- Site address
- 992 S. BOLMAR ST.
- City
- WEST CHESTER
- State
- PA
- ZIP
- 19382
- Mailing
- 992 S. BOLMAR ST., WEST CHESTER, PA 19382
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 56
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.243 C01 II A
- Issued
- Nov 4, 2013
- Penalty
- Initial $3,213 · Current $2,235 Reduced
General-duty citation text
29 CFR 1910.243(c)(1)(ii)(a): Safety guard on portable abrasive wheel were not mounted: a) 992 S. Bolmar St, West Chester, PA - Loading Dock - The employee was operating a 4½ inch, 10,000 rpm, Hilti angle grinder, Model #DAG 450-S, Serial #0025121Y, which did not have guard mounted on the portable abrasive wheel, thus exposing the employee to rotating parts hazards. This violation was observed on or about July 31, 2013. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $2235
- — Z (S) $3213
1910.252 B02 III
- Issued
- Nov 4, 2013
- Abate by
- Nov 8, 2013
- Penalty
- Initial $3,150 · Current $1,690 Reduced
General-duty citation text
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields: a) 992 S. Bolmar St, West Chester, PA - Shop Floor - Workers adjacent to the welding areas were not protected from rays by flameproof screens or shields, exposing the employees to optical hazards. This violation was observed on or about July 31, 2013. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $1690
- — Z (S) $3150
1910.303 G02 I
- Issued
- Nov 4, 2013
- Abate by
- Nov 8, 2013
- Penalty
- Initial $4,410 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets of other forms of approved enclosures, or other means listed under this provision: a) 992 S. Bolmar St, West Chester, PA - Drill Line - Energized parts of electrical equipment operating at 460 volts were not guarded against accidental contact. An employee would access the electrical cabinet of the Peddinghaus Spindle Drilling machine, Model #760 3/A, Serial #41051, using a ladder or standing on the machinery to gain access in order to reset the circuit breakers inside of the cabinet while the machine was energized, thus exposing the employee to a shock/electrocution hazard. This violation was observed on or about July 31, 2013. Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- — I (O) $2000
- — Z (S) $4410
More inspections at O'Rourke & Sons, INC.
View O'Rourke & Sons, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332312)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339246613.