RIFLE, CO ·
OSHA Inspection: ENTERPRISE PRODUCTS PARTNERS L.P.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of ENTERPRISE PRODUCTS PARTNERS L.P. in 27991 COUNTY ROAD 5, RIFLE, CO 81650 (NAICS 211112). OSHA activity number 339248171.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ENTERPRISE PRODUCTS PARTNERS L.P.
- Site address
- 27991 COUNTY ROAD 5
- City
- RIFLE
- State
- CO
- ZIP
- 81650
- Mailing
- 27991 COUNTY ROAD 5, RIFLE, CO 81650
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 211112
- Employees
- 38
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
1910.134 E01
- Issued
- Jan 28, 2014
- Abate by
- Mar 2, 2014
- Penalty
- Initial $3,400 · Current $0 Reduced
General-duty citation text
29 CFR 1910.134(f)(2): The employer did not ensure that employees using a tight-fitting facepiece respirator were fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) is used, or at least annually thereafter: (a) Enterprise Products Partners L.P. at 27991 County Road 5, Rifle CO: On and before 7/30/13, the employer did not ensure that employees required to use a tight-fitting facepiece respirator were fit tested annually. The employer required employees to wear a tight-fitting respirator during operations such as, but not limited to, sludge catcher filter change and TEG filter change. This condition potentially exposed employees to a respiratory hazard due to improper fit of the respirator.
Recent events (2)
- · I (S) $0
- · Z (S) $3400
1910.1028 E02 I
- Issued
- Jan 28, 2014
- Abate by
- May 1, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1028(e)(2)(i): The employer did not monitor each workplace and work operation to determine accurately the airborne concentrations of benzene to which employees may be exposed: (a) Enterprise Products Operating, LP at 27991 County Road 5, Rifle CO: On and before 7/30/13, the employer did not monitor each workplace and work operation to determine accurately the airborne concentrations of benzene to which employees may be exposed. The employer did not accurately determine employee exposure during operations such as, but not limited to, inlet separator filter change, rich and lean amine filter change. This condition potentially exposed employees to a respiratory hazard associated with benzene exposure.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.1028 E01 II
- Issued
- Jan 28, 2014
- Abate by
- May 1, 2014
- Penalty
- Initial $0 · Current $3,400
General-duty citation text
29 CFR 1910.1028(e)(1)(ii): Representative 8-hour TWA employee exposures were not determined on the basis of one sample or samples representing the full shift exposure for each job classification in each work area: (a) Enterprise Products Operating, LP at 27991 County Road 5, Rifle CO: On and before 7/30/13, the employer did not determine representative 8-hour TWA employee exposures on the basis of one sample or samples representing the full shift exposure for each job classification in each work area. The employer did not accurately determine employee exposure during operations such as, but not limited to, inlet separator filter change, rich and lean amine filter change. This condition potentially exposed employees to a respiratory hazard associated with benzene exposure.
Recent events (2)
- · I (O) $3400
- · Z (S) $0
1910.1028 E01 III
- Issued
- Jan 28, 2014
- Abate by
- May 1, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1028(e)(1)(iii): Determinations of compliance with the STEL were not made from 15-minute employee breathing zone samples measured at operations where there was reason to believe exposures were high: (a) Enterprise Products Operating, LP at 27991 County Road 5, Rifle CO: On and before 7/30/13, the employer did not take 15-minute employee breathing zone samples where there was a reason to believe exposures were high. The employer did not accurately determine employee exposure during operations such as, but not limited to, inlet separator filter change, rich and lean amine filter change. This condition potentially exposed employees to a respiratory hazard associated with benzene exposure.
Recent events (2)
- · I (O) $0
- · Z (S) $0
1904.32 B02 I
- Issued
- Jan 28, 2014
- Abate by
- Mar 2, 2014
- Penalty
- Initial $850 · Current $0 Reduced
General-duty citation text
29 CFR 1904.32(b)(2)(i): Total numbers of the columns on the OSHA 300 Log did not match the total numbers on the Annual Summary: (a) Enterprise Products Operating, LP at 27991 County Road 5, Rifle CO: On and before 7/30/13, the employer did not record the correct total number of injuries and illnesses from the OSHA 300 log on the Annual Summary for the calendar year 2012.
Recent events (2)
- · I (O) $0
- · Z (O) $850
1910.95 G06
- Issued
- Jan 28, 2014
- Abate by
- Mar 2, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.95(g)(6): At least annually after obtaining the baseline audiogram, the employer did not obtain a new audiogram for each employee exposed at or above an 8-hour time-weighted average of 85 decibels : (a) Enterprise Products Partners L.P. at 27991 County Road 5, Rifle CO: On and before 7/30/13, the employer did not obtain a new audiogram for each employee at least annually after obtaining the baseline audiogram. This condition exposes employees to the hazard of noise induced hearing loss.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Enterprise Products Partners L.P.
View Enterprise Products Partners L.P.'s full OSHA safety record →
More inspections in this industry (NAICS 211112)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339248171.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.