OSHA Inspection: TROY AMBULANCE SERVICE, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of TROY AMBULANCE SERVICE, INC. in 779 RIVER STREET, TROY, NY 12180 (NAICS 621910). OSHA activity number 339248874.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Troy Ambulance Service, INC. — free Get an email when a new federal OSHA severe-injury report for Troy Ambulance Service, INC. is published. One employer, no account, unsubscribe in one click.
Site address
779 RIVER STREET
City
TROY
State
NY
ZIP
12180
Mailing
P.O. BOX 438, COHOES, NY 12047
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
621910
Employees
60
Ownership type
A

5 citations on file for this inspection.

1910.37 A04

Serious Gravity 1 2 instances 60 exposed
Issued
Sep 20, 2013
Abate by
Oct 17, 2013
Penalty
Initial $2,100 · Current $1,050 Reduced
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times:    a)  First Floor Hallway - On and prior to August 2, 2013, the emergency lighting was not operational.         b)  Second Floor Sleeping Quarters - On and prior to August 2, 2013, the smoke detector alarm in the sleeping quarters was functional at the time of the inspection.
Recent events (2)
  • — I (S) $1050
  • — Z (S) $2100

1910.37 B02

Serious Gravity 1 3 instances 60 exposed
Issued
Sep 20, 2013
Abate by
Oct 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":  a)  First Floor Hallway Front Door - On and prior to August 2, 2013, an exit door at the front of the building (exiting to East side of building) did not have a sign with the word "EXIT".     b) First Floor Hallway Side Door - On and prior to August 2, 2013, an exit door at the side of the building (exiting to North side of building) did not have a sign with the word "EXIT".      c)  Second Floor Sleeping Quarters - On and prior to August 2, 2013, an exit door in the sleeping quarters did not have a sign with the word "EXIT".
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.37 B05

Serious Gravity 1 2 instances 60 exposed
Issued
Sep 20, 2013
Abate by
Oct 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet):  a)  First Floor Hallway - On and prior to August 2, 3013, doors that could be mistaken for an exit were not marked as "not an exit" or with the actual purpose.  Unmarked doors include but are not limited to the door leading to the sleeping quarters, the closet door, and the door leading to the Garage.  b)  Garage - On and prior to August 2, 2013, doors that could be mistaken for an exit were not marked as "not an exit" or with the actual purpose.  Unmarked doors include but are not limited to the door leading to the dispatch office and the door leading to the hallway.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.37 B06

Serious Gravity 1 1 instance 60 exposed
Issued
Sep 20, 2013
Abate by
Oct 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color:   a)  Garage South Wall Exit - On and prior to August 2, 2013, an exit sign above the door in the garage was not illuminated.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G02 I

Other-than-serious 1 instance 10 exposed
Issued
Sep 20, 2013
Abate by
Oct 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):  a)  First Floor Hallway - On and prior to August 2, 2013, the emergency lighting did not have cover, exposing live electrical components.