Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MANITOU CONSTRUCTION, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MANITOU CONSTRUCTION, INC. in 1810 26TH AVENUE SW, JAMESTOWN, ND 58401 (NAICS 237110). OSHA activity number 339251308.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Manitou Construction, INC. — free Get an email when a new federal OSHA severe-injury report for Manitou Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1810 26TH AVENUE SW
City
JAMESTOWN
State
ND
ZIP
58401
Mailing
700 GALLERIA PARKWAY SUITE 440, ATLANTA, GA 30339
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
23
Ownership type
A

7 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 5 exposed
Issued
Dec 11, 2013
Abate by
Dec 17, 2013
Penalty
Initial $2,800 · Current $2,800
Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fall and/or struck-by hazards:  (a) On or about July 24, 2013 and at times prior to that date, for the employees exposed to fall and/or struck-by hazards while riding in the excavator bucket of a Case CX240B hydraulic excavator as a means of entrance and egress into an excavation approximately 29 feet deep at 1810 26th Avenue SW in Jamestown, North Dakota.  Abatement Note: Among other methods, one feasible and acceptable abatement method to correct the hazard would be to follow the general safety requirements outlined in the Case CX240B Operator's Manual and the Association of Equipment Manufactures (AEM) Safety Manual for Hydraulic Excavator (HE-1004, April 2010).
Recent events (1)
  • — Z (S) $2800

1926.651 C02

Serious Gravity 10 1 instance 5 exposed
Issued
Dec 11, 2013
Abate by
Dec 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:  (a) On or about July 24, 2013 and at times prior to that date, for the employees exposed to cave-in hazards while installing sewer lines in an unprotected trench approximately 29 feet deep at 1810 26th Avenue SW, Jamestown, North Dakota.
Recent events (1)
  • — Z (S) $0

1926.21 B02

Serious Gravity 10 2 instances 5 exposed
Issued
Dec 11, 2013
Abate by
Jan 8, 2014
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury:  (a) On or about July 24, 2013 and at times prior to that date, for the employees exposed to excavation cave-in hazards while installing sewer lines in a trench approximately 29 feet deep without adequate protective system in place at 1810 26th Avenue SW, Jamestown, North Dakota.    (b) On or about July 24, 2013 and at times prior to that date, for the employees exposed to excavation cave-in hazards without a trained competent person on site while installing sewer lines in an unprotected trench approximately 29 feet deep at 1810 26th Avenue SW, Jamestown, North Dakota.
Recent events (1)
  • — Z (S) $2800

1926.651 K01

Serious Gravity 10 1 instance 5 exposed
Issued
Dec 11, 2013
Abate by
Dec 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems:  (a) On or about July 24, 2013 and at times prior to that date, for the employees exposed to cave-in hazards while installing sewer lines in an excavation approximately 29 feet deep without adequate protective systems in place at 1810 26th Avenue SW, Jamestown, North Dakota.
Recent events (1)
  • — Z (S) $0

1926.651 H01

Serious Gravity 5 1 instance 5 exposed
Issued
Dec 11, 2013
Abate by
Dec 17, 2013
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.651(h)(1): Employees were working in excavations in which there was accumulated water, or excavations in which water was accumulating, and adequate precautions had not been taken to protect employees against the hazards posed by water accumulation:  (a) On or about July 24, 2013 and at times prior to that date, for the employees exposed to cave-in hazards while installing sewer lines in an unprotected trench approximately 29 feet deep at 1810 26th Avenue SW, Jamestown, North Dakota.
Recent events (1)
  • — Z (S) $2000

1926.651 J02

Serious Gravity 5 1 instance 5 exposed
Issued
Dec 11, 2013
Abate by
Dec 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary:  (a) On or about July 24, 2013 and at times prior to that date, for the employees exposed to struck-by hazards where the spoil pile was immediately adjacent to the approximate 29 foot deep trench while installing sewer lines at 1810 26th Avenue SW, Jamestown, North Dakota.
Recent events (1)
  • — Z (S) $0

1926.652 A01

Serious Gravity 10 1 instance 5 exposed
Issued
Dec 11, 2013
Abate by
Dec 17, 2013
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section:  (a) On or about July 24, 2013 and at times prior to that date, for the employees installing sewer lines in a trench approximately 29 feet deep without an engineer designed protective system in place at 1810 26th Avenue SW, Jamestown, North Dakota.
Recent events (1)
  • — Z (S) $2800

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339251308.