RAMSEY, NJ ·
OSHA Inspection: LEEM/LSS FILTRATION, INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of LEEM/LSS FILTRATION, INC. in 25 ARROA STREET, RAMSEY, NJ 07446 (NAICS 333999). OSHA activity number 339252033.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LEEM/LSS FILTRATION, INC.
- Site address
- 25 ARROA STREET
- City
- RAMSEY
- State
- NJ
- ZIP
- 07446
- Mailing
- 25 ARROA STREET, RAMSEY, NJ 07446
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333999
- Employees
- 26
- Ownership type
- Private (A)
Citations
11 citations on file for this inspection.
1910.37 B04
- Issued
- Sep 17, 2013
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.37(b)(4): Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent: a) Shipping Department: Exit direction signs were not installed to assist employees in a case of emergency evacuation, on or about 08/07/13.
Recent events (2)
- · I (S) $1260
- · Z (S) $2100
1910.157 C01
- Issued
- Sep 17, 2013
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: a) Welding Area: Portable fire extinguisher was blocked by welding equipment, on or about 08/07/13. b) Welding Area: Portable fire extinguisher was blocked by pedestal fan and welding equipment, on or about 08/07/13.
Recent events (2)
- · I (S) $1260
- · Z (S) $2100
1910.157 G01
- Issued
- Sep 17, 2013
- Abate by
- Oct 11, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting: a) Facility: Portable fire extinguisher training was not provided for the employees, on or about 08/07/13.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.215 B09
- Issued
- Sep 17, 2013
- Abate by
- Oct 11, 2013
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.215(b)(9): 29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch. a) Welding Area: The distance between the Bench Grinder abrasive wheel periphery and a tongue guard was about three fourth (3/4) of an inch, on or about 08/07/13.
Recent events (2)
- · I (S) $1680
- · Z (S) $2800
1910.242 B
- Issued
- Sep 17, 2013
- Penalty
- Initial $1,785 · Current $1,071 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i. a) Wire Flattener Machine Area: Compress air used for metal part cleaning had pressure of 100 p.s.i., on or about 08/07/13.
Recent events (2)
- · I (S) $1071
- · Z (S) $1785
1910.253 B04 I
- Issued
- Sep 17, 2013
- Penalty
- Initial $3,500 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(i): Oxygen cylinders were stored near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire: a) Oxygen and Acetylene cylinders were stored together, on or about 08/07/13.
Recent events (2)
- · I (S) $2100
- · Z (S) $3500
1910.254 D09 III
- Issued
- Sep 17, 2013
- Abate by
- Oct 11, 2013
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.254(d)(9)(iii): Cables with damaged insulation or exposed bare conductors were not replace: a) Welding Area: A cable connecting a pedal switch and Miller Syncrowave 250 Welding Power Source had damaged insulation, on or about 08/07/13.
Recent events (2)
- · I (S) $1680
- · Z (S) $2800
1910.303 B01
- Issued
- Sep 17, 2013
- Abate by
- Oct 11, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees: a) Welding Area: Damaged cord with exposed metal conductor that powered a yellow pedestal air fan was not removed from use or replaced, on or about 08/07/13. b) Welding Area: Damaged cord that powered a black pedestal air fan was not removed from use or replaced, on or about 08/07/13.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.305 B01
- Issued
- Sep 17, 2013
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.305(b)(1): Unused openings in boxes, cabinets, or fittings were not effectively closed. a) Wedge Floor Department: An electrical junction box powered with 110 V had one (1) unused opening, on or about 04/26/2013. b) Wedge Floor Department: An electrical outlet box powered with 110 V had one (1) unused opening, on or about 08/07/13.
Recent events (2)
- · I (S) $1680
- · Z (S) $2800
1910.141 G02
- Issued
- Sep 17, 2013
- Abate by
- Oct 11, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.141(g)(2): Employees were permitted to consume food or beverage in area exposed to toxic materials: a) Welding Area: Employee had snacks and beverages in area exposed to toxic materials including, but not limited to, Methyl Ethyl Ketone, Methyl Methacrylate, and DYKEM Remover and Prep (contains Acetone, Isopropanol, and Ethanol), on or about 08/07/13.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.1200 E01
- Issued
- Sep 17, 2013
- Abate by
- Dec 1, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) Facility: Written hazard communication program was not developed for the workplace where employees worked with hazardous chemicals including, but not limited to, Methyl Ethyl Ketone, Methyl Methacrylate, and DYKEM Remover and Prep (contains Acetone, Isopropanol, and Ethanol), on or about 08/07/13.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 333999)