ALEXANDER, ND ·
OSHA Inspection: TRUSTLAND OILFIELD SERVICE, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of TRUSTLAND OILFIELD SERVICE, LLC in PETRO HUNT 150-102-6A-7-1H, ALEXANDER, ND 58831 (NAICS 213112). OSHA activity number 339256042.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TRUSTLAND OILFIELD SERVICE, LLC
- Site address
- PETRO HUNT 150-102-6A-7-1H
- City
- ALEXANDER
- State
- ND
- ZIP
- 58831
- Mailing
- P.O. BOX 849, NEW TOWN, ND 58763
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- Employees
- 90
- Ownership type
- A
Citations
4 citations on file for this inspection.
5(a)(1)
- Issued
- Dec 31, 2013
- Abate by
- Jan 28, 2014
- Penalty
- Initial $4,900 · Current $3,920 Reduced
General-duty citation text
Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees exposed to flash fires and explosions: (a) On or about July 16, 2013 for employees who were not protected from flash fires and explosions by the use of a lockout tagout program while performing maintenance work on a tank battery at the Petro Hunt 150-102-6A-7-1H well site near Alexander, ND. Abatement Note: Among other methods, one feasible and acceptable method of abatement would be to follow the recommended practices identified in the American Petroleum Institutes Recommended Practice for Occupational Safety for Oil and Gas Well Drilling and Servicing Operations API RP 54 section 6.9 Lockout/Tagout.
Recent events (2)
- · I (S) $3920
- · Z (S) $4900
1910.106 B06
- Issued
- Dec 31, 2013
- Abate by
- Jan 28, 2014
- Penalty
- Initial $4,900 · Current $3,920 Reduced
General-duty citation text
29 CFR 1910.106(b)(6): In locations where flammable vapors may be present, precautions were not taken to prevent ignition by eliminating or controlling sources of ignition. Sources of ignition may include open flames, lightning, smoking, hot surfaces, frictional heat, sparks (static, electrical, and mechanical), spontaneous ignition, chemical and physical-chemical reactions, and radiant heat: (a) On or about July 16, 2013 for employees who were exposed to flash fires and explosions while using electrical equipment and spark producing tools while performing maintenance work on a tank battery at the Petro Hunt 150-102-6A-7-1H well site near Alexander, ND.
Recent events (2)
- · I (S) $3920
- · Z (S) $4900
1910.307 C
- Issued
- Dec 31, 2013
- Abate by
- Jan 28, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location: (a) On or about July 16, 2013 for employees who were exposed to flash fires and explosions while using electrical equipment and spark producing tools while performing maintenance work on a tank battery at the Petro Hunt 150-102-6A-7-1H well site near Alexander, ND.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.132 A
- Issued
- Dec 31, 2013
- Abate by
- Jan 28, 2014
- Penalty
- Initial $4,900 · Current $3,920 Reduced
General-duty citation text
29 CFR 1910.132(a): The employer did not provide and ensure the use of protective equipment, including personal protective equipment (PPE), used to comply with this part, at no cost to employees: (a) On or about July 16, 2013 for employees with exposure to flash fires and explosions where the employer had not provided and ensured the use of fire resistant clothing (FRC) while performing maintenance work on a tank battery at the Petro Hunt 150-102-6A-7-1H well site near Alexander, ND.