Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,249Inspections Most recent open 2026-08-20 Last loaded 2026-08-24

OSHA Inspection: NATIONAL OILWELL VARCO

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NATIONAL OILWELL VARCO in 2530 GARROW ST., HOUSTON, TX 77003 (NAICS 333132). OSHA activity number 339264319.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch National Oilwell Varco for free Get an email when a new federal OSHA severe-injury report for National Oilwell Varco is published. One employer, no account, unsubscribe in one click.
Site address
2530 GARROW ST.
City
HOUSTON
State
TX
ZIP
77003
Mailing
2530 GARROW ST., HOUSTON, TX 77003
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333132
Employees
52
Ownership type
Private (A)

6 citations on file for this inspection.

1910.178 P01

Deleted Serious Gravity 5 1 instance 52 exposed
Issued
Dec 19, 2013
Abate by
Dec 30, 2013
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition(s):  a) On or about the August 06, 2013 in the shipping/receiving department the Caterpillar forklift with serial number AT13D35278 was used without having the reverse alarm working.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2800

1910.179 J03

Deleted Serious Gravity 10 1 instance 52 exposed
Issued
Dec 19, 2013
Abate by
Jan 7, 2014
Penalty
Initial $4,900 · Current $0 Reduced
29 CFR 1910.179(j)(3): A complete periodic inspection of crane(s) had not been conducted in the past 12 months:  a) On or about August 6, 2012 in the machine shop area the 30 Ton gantry/hoist crane (equipment number 18) had not been inspected annually.
Recent events (2)
  • · I (S) $0
  • · Z (S) $4900

1910.184 C06

Serious Gravity 10 1 instance 52 exposed
Issued
Dec 19, 2013
Abate by
Dec 30, 2013
Penalty
Initial $0 · Current $2,380
29 CFR 1910.184(c)(6): Slings were not securely attached to their loads:    a) On or about August 6, 2013, in the machine shop area the gantry/hoist crane (equipment number 18) was did not have the slings securely attached to the load in that the safety latch of the hook was missing.
Recent events (2)
  • · I (S) $2380
  • · Z (S) $0

1910.179 J03 X

Deleted Serious Gravity 5 1 instance 52 exposed
Issued
Dec 19, 2013
Abate by
Dec 30, 2013
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1910.179(j)(3)(x): Electrical apparatus were not inspected periodically for signs of pitting or any deterioration of controller contactors, limit switches and pushbutton stations:  a) On or about August 6, 2013 in the machine shop area the controls on the 30 Ton gantry/hoist crane (equipment number 18) had not been inspected periodically.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2800

1910.179 L03 III D

Serious Gravity 5 1 instance 52 exposed
Issued
Dec 19, 2013
Abate by
Dec 30, 2013
Penalty
Initial $0 · Current $2,380
29 CFR 1910.179(l)(3)(iii)(d): Pendant control stations were not kept clean, and/or their function labels were not kept legible:    a) On or about August 6, 2013 in the machine shop the labels on the controls of the gantry/hoist crane (equipment 18) were not legible.
Recent events (2)
  • · I (S) $2380
  • · Z (S) $0

1910.303 F02

Serious Gravity 5 2 instances 5 exposed
Issued
Dec 19, 2013
Abate by
Dec 30, 2013
Penalty
Initial $3,500 · Current $2,380 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:    a) On or about August 6, 2013, in the assembly room, the switches in the 480 volt breaker box located in the southwest part of were not labeled.    b) On or about August 6, 2013, in the assembly room, the switches in the 120 volt breaker box located in the southwest part of the room were not labeled.
Recent events (2)
  • · I (S) $2380
  • · Z (S) $3500

View National Oilwell Varco's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339264319.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.