OSHA Inspection: SAFE FLOW UTILITIES

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SAFE FLOW UTILITIES in 8240 TELEPHONE ROAD, HOUSTON, TX 77061 (NAICS 237110). OSHA activity number 339265100.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Safe Flow Utilities — free Get an email when a new federal OSHA severe-injury report for Safe Flow Utilities is published. One employer, no account, unsubscribe in one click.
Establishment
SAFE FLOW UTILITIES
Site address
8240 TELEPHONE ROAD
City
HOUSTON
State
TX
ZIP
77061
Mailing
5380 ANDERSON ROAD, HOUSTON, TX 77053
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
3
Ownership type
A

2 citations on file for this inspection.

1926.651 C02

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 26, 2013
Abate by
Sep 3, 2013
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:    At the site, in a trench, where no ladder was present, the employee was exposed to engulfment and struck by hazards.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1926.652 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 26, 2013
Abate by
Sep 3, 2013
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c). The employer had not complied with the provisions of 29 CFR 1926.652(b)(1)(i) in that that:     At the site,  an employee was unprotected in a trench which was greater than five feet in depth, without protective systems, exposing the employee to engulfment and struck by hazards.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

View Safe Flow Utilities's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339265100.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.