Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: INNOVATIVE THERMOPLASTICS, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of INNOVATIVE THERMOPLASTICS, INC. in 128 LOUISIANA ST, SAN ANTONIO, TX 78210 (NAICS 326199). OSHA activity number 339272643.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Innovative Thermoplastics, INC. — free Get an email when a new federal OSHA severe-injury report for Innovative Thermoplastics, INC. is published. One employer, no account, unsubscribe in one click.
Site address
128 LOUISIANA ST
City
SAN ANTONIO
State
TX
ZIP
78210
Mailing
128 LOUISIANA ST, SAN ANTONIO, TX 78210
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
1
Ownership type
A

6 citations on file for this inspection.

1910.22 D01

Serious Gravity 5 2 instances 1 exposed
Issued
Nov 18, 2013
Abate by
Dec 1, 2013
Penalty
Initial $2,000 · Current $800 Reduced
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate:    (a) Warehouse, northeast side: On or about August 8, 2013, employees were exposed to a struck-by hazard from materials that were stored above an area used for office space that was not rated for a load capacity or for storage use.    (b) Warehouse, northwest side: On or about August 8, 2013, employees were exposed to a struck-by hazard from materials that were stored above an area used for the employee breakroom and for restroom facilities that was not rated for a load capacity or for storage use.
Recent events (3)
  • — F (S) $800
  • — C (S) $2000
  • — Z (S) $2000

1910.212 B

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 18, 2013
Abate by
Dec 1, 2013
Penalty
Initial $1,600 · Current $700 Reduced
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:    Warehouse, North side: On or about August 8, 2013, employee(s) were exposed to struck-by and caught-in hazards from an unachored drill press (Model FDM16(1516F)) which was used for fabrication processes.
Recent events (3)
  • — F (S) $700
  • — C (S) $1600
  • — Z (S) $1600

1910.243 C01 II A

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 18, 2013
Abate by
Dec 1, 2013
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1910.243(c)(1)(ii)(a): Safety guard(s) for portable abrasive wheel(s) did not cover the spindle end, and flange projections:    Warehouse, north side: On or about August 8, 2013 employee(s) were exposed to a struck-by hazard from the use of a Makita Angle Grinder (Model 9557PB) which was not fitted with a wheel guard.
Recent events (3)
  • — F (S) $800
  • — C (S) $1600
  • — Z (S) $1600

1910.305 B01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 18, 2013
Abate by
Dec 1, 2013
Penalty
Initial $1,600 · Current $500 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    Warehouse, South side: On or about August 8, 2013, employee(s) were exposed to an electrical hazard from  an electrical panel box which was lacking blank panels to effectively close the box.
Recent events (3)
  • — F (S) $500
  • — C (S) $1600
  • — Z (S) $1600

1910.305 B02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 18, 2013
Abate by
Dec 1, 2013
Penalty
Initial $2,400 · Current $800 Reduced
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:    Warehouse, north side: On or about August 8, 2013, employee(s) were exposed to an electrical hazard from an eletrical outlet box with an open faceplate which was used for a Power Cat portable blower (Model: D400XLH).
Recent events (3)
  • — F (S) $800
  • — C (S) $2400
  • — Z (S) $2400

1910.1200 B04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 18, 2013
Abate by
Jan 31, 2014
Penalty
Initial $2,000 · Current $400 Reduced
29 CFR 1910.1200(b)(4)(i): In work operations where employees only handle chemicals in sealed containers which are not opened under normal conditions of use, the employer did not ensure that labels on incoming containers of hazardous chemicals were not removed or defaced:    Warehouse, west side: On or about August 8, 2013, employee(s) where exposed to chemical hazards from chemical containers which were stored in a plastic cabinet labeled "Organic Peroxides" and were not clearly marked with the chemical contents or hazard specifications.
Recent events (3)
  • — F (S) $400
  • — C (S) $2000
  • — Z (S) $2000

View Innovative Thermoplastics, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339272643.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.