OSHA Inspection: HALCON RESOURCES CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HALCON RESOURCES CORPORATION in STASNY-HONZA 1-H, COLLEGE STATION, TX 77840 (NAICS 213112). OSHA activity number 339272882.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Halcon Resources Corporation — free Get an email when a new federal OSHA severe-injury report for Halcon Resources Corporation is published. One employer, no account, unsubscribe in one click.
Site address
STASNY-HONZA 1-H
City
COLLEGE STATION
State
TX
ZIP
77840
Mailing
700 LOUISIANA STREET SUITE 6700, HOUSTON, TX 77002
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
Employees
1
Ownership type
A

2 citations on file for this inspection.

1910.157 C01

Other-than-serious 1 instance 2 exposed
Issued
Sep 30, 2013
Penalty
Initial $3,000 · Current $4,200
29 CFR 1910.157(c)(1): Employer did not provide portable fire extinguishers which were mounted, located, and identified, so as to be readily accessible for employee use:    On or about August 7, 2013 portable fire extinguishers were not provided in the company trailer, exposing employees to a fire hazard.
Recent events (2)
  • — I (O) $4200
  • — Z (S) $3000

1910.305 G02 III

Other-than-serious 1 instance 2 exposed
Issued
Sep 30, 2013
Penalty
Initial $4,000 · Current $0 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:    On or about August 7, 2013 the 220 Volt cord connecting the company trailer to the generator did not have a strain relief device.  The cord was too small for the plug provided leaving the wire loose around the other sheath.  The generator was located near the company trailer, exposing employees to an electrical hazard.
Recent events (2)
  • — I (O) $0
  • — Z (S) $4000

View Halcon Resources Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339272882.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.