PITTSBURGH, PA —
OSHA Inspection: BRIDGES
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BRIDGES in 811 EAST CARSON STREET, PITTSBURGH, PA 15203 (NAICS 236220). OSHA activity number 339276677.
Where did this inspection happen?
- Establishment
- BRIDGES
- Site address
- 811 EAST CARSON STREET
- City
- PITTSBURGH
- State
- PA
- ZIP
- 15203
- Mailing
- 209 PINE CREEK ROAD, WEXFORD, PA 15090
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 1
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.403 B02
- Issued
- Penalty
- Initial $2380.00 · Current $2380.00
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a) Jobsite, 811 East Carson Street, Pittsburgh, PA: On or about August 9, 2013, a metal quad box was lying on the floor being used to power office equipment and was not being used in accordance with the listing and labeling instructions.
Recent events (2)
- — I (O) $2380
- — Z (S) $2380
1926.405 G02 IV
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: a) Jobsite, 811 East Carson Street, Pittsburgh, PA: On or about August 9, 2013, the electric cord on the Dayton fan # 400100, was not provided with adequate strain relief at its attachment plug. b) Jobsite, 811 East Carson Street, Pittsburgh, PA: On or about August 9, 2013, the electric cord on the metal quad box was not provided with adequate strain relief at its attachment plug.
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections at BRIDGES
STATE COLLEGE, PA—2004-02-05 00:00:00
BRIDGES
View BRIDGES's full OSHA safety record →
More inspections in this industry (NAICS 236220)
IRVINE, CA—2026-07-13
SNEARY CONSTRUCTION, INC.
IRVINE, CA—2026-07-13
KUKBO DESIGN USA LLC
SIOUX FALLS, SD—2026-07-13
REM CONSTRUCTION SERVICES, LLC
INDIAN ROCKS BEACH, FL—2026-07-10
UNKNOWN CONTRACTOR
SIOUX FALLS, SD—2026-07-10
HENRY CARLSON COMPANY
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source