Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CAP GLASS, LLC

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of CAP GLASS, LLC in 799 SMITH LANE, NORTHAMPTON, PA 18067 (NAICS 423930). OSHA activity number 339277659.

Watch CAP Glass, LLC — free Get an email when a new federal OSHA severe-injury report for CAP Glass, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
CAP GLASS, LLC
Site address
799 SMITH LANE
City
NORTHAMPTON
State
PA
ZIP
18067
Mailing
799 SMITH LANE, NORTHAMPTON, PA 18067
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423930
Employees
18
Ownership type
A

5 citations on file for this inspection.

1910.37 A04

Serious Gravity 1 4 instances 4 exposed
Issued
Penalty
Initial $1200.00 · Current $720.00 Reduced
29 CFR 1910.37(a)(4): Safeguards designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting) must be in proper working order at all times.  a) Production area South wall- On or about July 17, 2013, an emergency light would not illuminate when the test button was pushed, which would not provide the required illumination for employee egress in the event of emergency power loss.  b) Production area East wall- On or about July 17, 2013, an emergency light would not illuminate when the test button was pushed, which would not provide the required illumination for employee to egress in the event of power loss.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

1910.132 D01

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $960.00 Reduced
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards were present, or were likely to be present, which necessitated the use of personal protective equipment.  1) Facility wide - On or about July 17, 2013, employees were working in areas with electrical, eye, and hand hazards without the employer assessing the workplace to determine which personal protective equipment was necessary for proper employee protection.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.178 L01 II

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $1600.00 · Current $960.00 Reduced
29 CFR 1910.178(l)(1)(ii): The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a forklift.  a) Facility wide - On or about July 17, 2013, employees observed operating a forklift had not successfully completed the training necessary for safe operation prior to their initial usage.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.303 G02 I

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $2800.00 · Current $1680.00 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):  a) Electrical switch gear room - On or about July 17, 2013, employees were working in the area of multiple electrical control cabinets with exposed live parts energized to 277 Volts AC that were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.333 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1910.333(b)(2): While an employee was exposed to contact with parts of fixed electric equipment or circuits which were deenergized, the circuits energizing the parts were not locked out or tagged or both in accordance with the requirements of this paragraph (b) of 29 CFR 1910.333(b)(2):  a) Switch gear room - On or about July 17, 2013 employees were working on a 277 VAC motor control center with exposed, unprotected live parts that had not had the appropriate lockout devices or tagout devices affixed to isolate the electrical power and to prevent unexpected energization, start up or release of the stored energy as a control measure to prevent injury to the employees.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000