WILKES BARRE, PA ·
OSHA Inspection: KI GARZELLA ELECTRICAL CONTRACTOR
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of KI GARZELLA ELECTRICAL CONTRACTOR in 110 SCHECHTER DRIVE, WILKES BARRE, PA 18702 (NAICS 238210). OSHA activity number 339279234.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KI GARZELLA ELECTRICAL CONTRACTOR
- Site address
- 110 SCHECHTER DRIVE
- City
- WILKES BARRE
- State
- PA
- ZIP
- 18702
- Mailing
- 109 OAK STREET, PITTSTON, PA 18640
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 2
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1926.501 B01
- Issued
- Aug 22, 2013
- Penalty
- Initial $1,020 · Current $600 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. (a) Patio roof on southwest side of building, 110 Schechter Drive, Wilkes-Barre Township, PA: Employees removed light fixtures from the southwest wall of the building without any means of fall protection while on a patio roof that ranged in height from eight-foot two-inches (8'2") to ten-foot, two-inches (10'2"). Employees were exposed to a fall hazard, on or about August 6, 2013. In accordance with 29 CFR 1903.19(c), abatement certification is not required for this violation. Abatement was observed during the inspection.
Recent events (2)
- · I (S) $600
- · Z (S) $1020
1926.1053 B01
- Issued
- Aug 22, 2013
- Penalty
- Initial $1,020 · Current $600 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Because of the portable ladder's length, the ladder side rails did not extend to at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access and the ladder was not secured at its top to a rigid support that will not deflect, with a grasping device, such as a grabrail, provided to assist employees in mounting and dismounting the ladder: (a) Patio roof on southwest side of building, 110 Schechter Drive, Wilkes-Barre Township, PA: Employees accessed a roof using a six-foot (6') portable step-ladder without a rigid support, without a grasping device, and without side rails that extended at least 3-feet above the eight-foot, two-inch (8'2") roof height. Employees were exposed to a fall hazard, on or about August 6, 2013. In accordance with 29 CFR 1903.19(c), abatement certification is not required for this violation. Abatement was observed during the inspection.
Recent events (2)
- · I (S) $600
- · Z (S) $1020
1926.1053 B13
- Issued
- Aug 22, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: (a) Patio roof on southwest side of building, 110 Schechter Drive, Wilkes-Barre Township, PA: Employees used the top of a six-foot (6') portable step-ladder to access an eight-foot, two-inch (8'2") high roof. Employees were exposed to a fall hazard, on or about August 6, 2013. In accordance with 29 CFR 1903.19(c), abatement certification is not required for this violation. Abatement was observed during the inspection.