OSHA Inspection: NAVAL SUPPLY SYSTEMS COMMAND, FALLON

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NAVAL SUPPLY SYSTEMS COMMAND, FALLON in 4755 PASTURE ROAD, BLDG 64 NAS FALLON, FALLON, NV 89496 (NAICS 541614). OSHA activity number 339282295.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Naval Supply Systems Command, Fallon — free Get an email when a new federal OSHA severe-injury report for Naval Supply Systems Command, Fallon is published. One employer, no account, unsubscribe in one click.
Site address
4755 PASTURE ROAD, BLDG 64 NAS FALLON
City
FALLON
State
NV
ZIP
89496
Mailing
4755 PASTURE ROAD, BLDG 64 NAS FALLON, FALLON, NV 89496
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
541614
Employees
150
Ownership type
D

4 citations on file for this inspection.

1910.37 B02

Serious Gravity 1 1 instance 150 exposed
Issued
Aug 30, 2013
Abate by
Sep 25, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(2):   Each exit was not clearly visible and marked by a sign reading "Exit":  (a)  On or about July 30, 2013, Bldg 25, in the supply receiving cage area, the exit door did not have a sign reading "EXIT".
Recent events (1)
  • — Z (S) $0

1910.213 C01

Serious Gravity 1 1 instance 150 exposed
Issued
Aug 30, 2013
Abate by
Sep 25, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut.  (a) On or about July 30, 2013, Supply Bldg 64, the unisaw Delta X table saw had a broken and damaged guard.
Recent events (1)
  • — Z (S) $0

1910.303 B02

Serious Gravity 5 1 instance 150 exposed
Issued
Aug 30, 2013
Abate by
Sep 25, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  (a) On or about July 30, 2013, Supply Recieiving area, material handler's desk,  there was two permanently mounted re-locatable power taps.
Recent events (1)
  • — Z (S) $0

1910.305 G01 IV A

Serious Gravity 5 1 instance 150 exposed
Issued
Aug 30, 2013
Abate by
Sep 25, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A):   Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure.  (a) On or about July 30, 2013, Supply Bldg 25, an orange extension cord was used to extend power to the Hitachi miter saw for more than 90 days.
Recent events (1)
  • — Z (S) $0

View Naval Supply Systems Command, Fallon's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339282295.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.