ALBANY, NY ·
OSHA Inspection: WHITING-TURNER CONTRACTING COMPANY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WHITING-TURNER CONTRACTING COMPANY in UNIVERSITY OF ALBANY 1400 WASHINGTON AVENUE, ALBANY, NY 12222 (NAICS 236220). OSHA activity number 339284234.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WHITING-TURNER CONTRACTING COMPANY
- Site address
- UNIVERSITY OF ALBANY 1400 WASHINGTON AVENUE
- City
- ALBANY
- State
- NY
- ZIP
- 12222
- Mailing
- 1 SPEEN STREET, FRAMINGHAM, MA 01701
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 2000
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1926.404 B01 I
- Issued
- Sep 3, 2013
- Penalty
- Initial $1,951 · Current $0 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites: (a) Press Level - on or about August 12, 2013 - Hilti TE6-S Drill, serial# 343323 was not protected by a Ground Fault Circuit Interrupter (GFCI). (b) Main Concourse - on or about August 12, 2013 - Ridgid Pipe Threader, model# 1224, serial# EB36599 1009; and Milwaukee Band Saw, model# 6230N, serial# C05AD09261565 were not protected by a Ground Fault Circuit Interrputer (GFCI).
Recent events (3)
- · J (S) $0
- · C (S) $1951
- · Z (S) $1951
1926.404 F06
- Issued
- Sep 3, 2013
- Penalty
- Initial $1,951 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: (a) Main Concourse - on or about August 12, 2013 - Milwaukee Band Saw, model# 6230N, serial# C05AD09261565; and Ridgid Pipe Threader, model# 1224, serial# EB36599 1009, were not provided with a continual path to ground.
Recent events (3)
- · J (S) $1000
- · C (S) $1951
- · Z (S) $1951
More inspections at Whiting-Turner Contracting Company
View Whiting-Turner Contracting Company's full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339284234.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.