Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RASCON PRECAST & STONE, LLC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RASCON PRECAST & STONE, LLC. in 9306 SCHULZE DRIVE, WEST CHESTER, OH 45069 (NAICS 238140). OSHA activity number 339286262.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rascon Precast & Stone, LLC. — free Get an email when a new federal OSHA severe-injury report for Rascon Precast & Stone, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
9306 SCHULZE DRIVE
City
WEST CHESTER
State
OH
ZIP
45069
Mailing
219 PIONEER BLVD., UNIT A, SPRINGBORO, OH 45066
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
14
Ownership type
A

4 citations on file for this inspection.

1926.451 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 23, 2013
Abate by
Jan 21, 2014
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:    (a)  On or about August 8, 2013, an employee was observed mixing mortar in a mud pan on top of a self-supporting, tubular, welded frame scaffold that was not fully planked in that there were only four planks, instead of six planks, thereby exposing employees to a fall in excess of 22 feet.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.451 B05 II

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 23, 2013
Abate by
Jan 21, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.451(b)(5)(ii): Each platform greater than 10 feet in length shall not extend over its support more than 18 inches (46 cm), unless it is designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end.  (a)  On or about August 8, 2013, an employee was observed mixing mortar in a mud pan on top of a self-supporting, tubular, welded frame scaffold that had a work platform that extended out more than 18 inches past its support, thereby exposing employees to a fall in excess of 22 feet.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 23, 2013
Abate by
Jan 21, 2014
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Cross braces shall not be used as a means of access:    (a)  On or about August 8, 2013, employees were observed using the cross braces on a self-supporting tubular welded frame scaffold, to gain access to the work platform where the mud pan was located, thereby exposing them to fall potential in excess of 22 feet.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.451 G01

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 23, 2013
Abate by
Jan 21, 2014
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers:    (a)  On or about August 8, 2013, employees working from the top of a self-supporting, tubular, welded frame scaffold, were not protected by standard guardrails or a personal fall arrest system, thereby exposing them to falls in excess of 22 feet.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000