Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: NAVAL AIR STATION FALLON, PWD ENVIRONMENTAL DIVISION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NAVAL AIR STATION FALLON, PWD ENVIRONMENTAL DIVISION in 4755 PASTURE ROAD, B-307 NAS FALLON, FALLON, NV 89496 (NAICS 541330). OSHA activity number 339291155.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Naval AIR Station Fallon, PWD Environmental Division for free Get an email when a new federal OSHA severe-injury report for Naval AIR Station Fallon, PWD Environmental Division is published. One employer, no account, unsubscribe in one click.
Site address
4755 PASTURE ROAD, B-307 NAS FALLON
City
FALLON
State
NV
ZIP
89496
Mailing
4755 PASTURE ROAD, B-307 NAS FALLON, FALLON, NV 89496
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
541330
Employees
48
Ownership type
Federal government (D)

4 citations on file for this inspection.

1910.36 G02

Serious Gravity 1 2 instances 48 exposed
Issued
Sep 9, 2013
Abate by
Oct 2, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points.  (a) On or about July 31, 2013, in the environmental engineer and environmental assistant's office spaces, exit/egress were 20, 23, and 26 inches wide and obstructed by metal file cabinet and desks for records.
Recent events (1)
  • · Z (S) $0

1910.303 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 9, 2013
Abate by
Oct 2, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees, in that the employer did not ensure the safety of the equipment pursuant to the considerations in sections (i) through (viii) of 29 CR 1910.303(b)(1).  (a) On or about July 31, 2013, at the NEPA coordinator's cubicle, the quadruplex electrical wall outlet, had a ground pin stuck in the receptacle outlet.
Recent events (1)
  • · Z (S) $0

1910.303 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 9, 2013
Abate by
Oct 2, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling.  (a) On or about July 31, 2013, a re-locatable power tap was used to plug-in high amperage electrical equipment such as a coffee maker, water heater, oscillating fan, etc.,
Recent events (1)
  • · Z (S) $0

1910.305 G01 IV A

Serious Gravity 1 1 instance 2 exposed
Issued
Sep 9, 2013
Abate by
Oct 2, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A):   Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure.  (a) On or about July 31, 2013, a black extension cord was used to extend power to the an oscillating fan for more than 90 days.
Recent events (1)
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339291155.