OSHA Inspection: VISION MASONRY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of VISION MASONRY in 1808 MAIN STREET, KANSAS CITY, MO 64108 (NAICS 238140). OSHA activity number 339297079.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Vision Masonry — free Get an email when a new federal OSHA severe-injury report for Vision Masonry is published. One employer, no account, unsubscribe in one click.
Establishment
VISION MASONRY
Site address
1808 MAIN STREET
City
KANSAS CITY
State
MO
ZIP
64108
Mailing
7406 E 199TH ST, BELTON, MO 64012
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
2
Ownership type
A

5 citations on file for this inspection.

1926.451 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 9, 2013
Penalty
Initial $2,800 · Current $840 Reduced
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:    (a). Jobsite at 1808 Main Street, Kansas City, MO:  Employees were exposed to a fall hazard while working on the top of the scaffolding that had only one plank at the working level leaving most of the area between the scaffolding up rights and midguard rail unplanked.
Recent events (2)
  • — I (S) $840
  • — Z (S) $2800

1926.451 E01

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 9, 2013
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.    (a). Job site at 1808 Main St, Kansas City, MO: Employees were observed climbing onto scaffolding using the cross braces and not the access ladders exposing them to a fall hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

1926.451 G04 II

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 9, 2013
Penalty
Initial $2,800 · Current $840 Reduced
29 CFR 1926.451(g)(4)(ii): The top edge height of toprails or equivalent member on supported scaffolds manufactured or placed in service after January 1, 2000 shall be installed between 38 inches (0.97 m) and 45 inches (1.2 m) above the platform surface. The top edge height on supported scaffolds manufactured and placed in service before January 1, 2000, and on all suspended scaffolds where both a guardrail and a personal fall arrest system are required shall be between 36 inches (0.9 m) and 45 inches (1.2 m). When conditions warrant, the height of the top edge may exceed the 45-inch height, provided the guardrail system meets all other criteria of paragraph (g)(4).    (a). Jobsite at 1808 Main Street, Kansas City, MO: An employee was exposed to a fall hazard while working on top of scaffolding on scaffold with a guardrail below or less then 36 inches.The distance between the top of the top guardrail to the ground was approximately 14.5 feet.
Recent events (2)
  • — I (S) $840
  • — Z (S) $2800

1926.452 C02

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 9, 2013
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1926.452(c)(2): Frames and panels shall be braced by cross, horizontal, or diagonal braces, or combination thereof, which secure vertical members together laterally. The cross braces shall be of such length as will automatically square and align vertical members so that the erected scaffold is always plumb, level, and square. All brace connections shall be secured.    (a). At 1808 Main Street, in Kansas City, MO: The employer failed to ensure that the scaffold had all the brace connections secured and in place before the employees were allowed to work on it. Employees were exposed to fall hazard in that the employees were using a scaffold without all the required brace connections.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

1926.451 F03

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Sep 9, 2013
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1926.451(f)(3): Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.  (a). Work was being performed on the building at 1808 Main Street, Kansas City,MO: The employer failed to inspect and ensure that the scaffold being used by the employees was properly inspected and secured before the employees were allowed to work on it. The employees were exposed to fall hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

View Vision Masonry's full OSHA safety record →