OSHA Inspection: HOLMAN BOILER WORKS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HOLMAN BOILER WORKS in 12019 STARCREST, SAN ANTONIO, TX 78247 (NAICS 333414). OSHA activity number 339298036.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Holman Boiler Works for free Get an email when a new federal OSHA severe-injury report for Holman Boiler Works is published. One employer, no account, unsubscribe in one click.
Establishment
HOLMAN BOILER WORKS
Site address
12019 STARCREST
City
SAN ANTONIO
State
TX
ZIP
78247
Mailing
1956 SINGLETON BLVD, DALLAS, TX 75212
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333414
Employees
11
Ownership type
A

2 citations on file for this inspection.

1910.22 D01

Other-than-serious 1 instance 10 exposed
Issued
Nov 19, 2013
Abate by
Dec 22, 2013
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.22(d)(1):   In every building or other structure, or part thereof, used for mercantile, business, industrial, or storage purposes, the loads approved by the building official were not marked on plates of approved design which shall be supplied and securely affixed by the owner of the building, or his duly authorized agent, in a conspicuous place in each space to which they relate:    Upper storage floor, southeast corner of warehouse.  On or about August 14, 2013, employees were exposed to a struck-by hazard of the upper storage floor collapsing from the weight of significantly heavy items such as, but not limited to, lengths of industrial strength steam and hot water flexible tubing, while they worked underneath retrieving tools, and performing administrative duties.
Recent events (2)
  • · I (O) $960
  • · Z (S) $1600

1910.253 B04 III

Other-than-serious 1 instance 10 exposed
Issued
Nov 19, 2013
Abate by
Dec 7, 2013
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.253(b)(4)(iii):   Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials a minimum distance of 20 feet or by a noncombustible barrier at least 5 feet high having a fire-resistance rating of at least one-half hour:    North wall of warehouse.  On or about August 14, 2013, employees were exposed to burns from fire and explosion, as cylinders of oxygen were stored directly adjacent to cylinders of acetylene, in the warehouse where they moved supplies and equipment.
Recent events (2)
  • · I (O) $1200
  • · Z (S) $2000

View Holman Boiler Works's full OSHA safety record →