Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: LEAM DRILLING SYSTEMS, LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of LEAM DRILLING SYSTEMS, LLC in 11107 31P STREET, DICKINSON, ND 58601 (NAICS 213112). OSHA activity number 339301327.

Watch Leam Drilling Systems, LLC — free Get an email when a new federal OSHA severe-injury report for Leam Drilling Systems, LLC is published. One employer, no account, unsubscribe in one click.
Site address
11107 31P STREET
City
DICKINSON
State
ND
ZIP
58601
Mailing
11107 31P STREET, DICKINSON, ND 58601
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
Employees
13
Ownership type
A

4 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $5000.00 · Current $2500.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point-of-operation, ingoing nip points, rotating parts, flying chips and/or sparks:    (a) On or about August 15, 2013, for employees exposed to ingoing nip points while operating the Kingston Oil Country 30-foot lathe without using a chuck guard at Leam Drilling Systems, LLC at 11107 31P Street, Dickinson, North Dakota.    (b) On or about August 15, 2013, and at times prior, for employees exposed to ingoing nip points while operating the Jet GH 1640ZX lathe without a chuck guard at Leam Drilling Systems, LLC at 11107 31P Street, Dickinson, North Dakota.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $5000

1910.303 G02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $5000.00 · Current $2500.00 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    (a) On August 15, 2013, and at times prior, for employees cleaning and inspecting pipe at Leam Drilling Systems, LLC at 11107 31P Street, Dickinson, North Dakota.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $5000

1910.305 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(e)(1): Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations were not installed to prevent moisture or water from entering and accumulating within the enclosures:  (a) On August 15, 2013, and at times prior, for employees exposed to electrical hazards while cleaning and inspecting pipe at Leam Drilling Systems, LLC at 11107 31P Street, Dickinson, North Dakota.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.334 A03 I

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.334(a)(3)(i): A flexible cord used with grounding type equipment did not contain an equipment grounding conductor:  (a)  On August 15, 2013, and at times prior, for employees exposed to electrical hazards while cleaning and inspecting pipe at Leam Drilling Systems, LLC at 11107 31P Street, Dickinson, North Dakota.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339301327.