Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TFO TECH CO., LTD

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of TFO TECH CO., LTD in 221 STATE STREET, JEFFERSONVILLE, OH 43128 (NAICS 336312). OSHA activity number 339303042.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch TFO Tech CO., LTD — free Get an email when a new federal OSHA severe-injury report for TFO Tech CO., LTD is published. One employer, no account, unsubscribe in one click.
Establishment
TFO TECH CO., LTD
Site address
221 STATE STREET
City
JEFFERSONVILLE
State
OH
ZIP
43128
Mailing
221 STATE STREET, JEFFERSONVILLE, OH 43128
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336312
Employees
160
Ownership type
A

5 citations on file for this inspection.

1910.147 C04 I

Deleted Repeat Gravity 5 1 instance 4 exposed
Issued
Feb 4, 2014
Abate by
Mar 24, 2014
Penalty
Initial $9,900 · Current $0 Reduced
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.  Note: Exception: The employer need not document the required procedure for a particular machine or equipment, when all of the following elements exist: (1) The machine or equipment has no potential for stored or residual energy or reaccumulation of stored energy after shut down which could endanger employees; (2) the machine or equipment has a single energy source which can be readily identified and isolated; (3) the isolation and locking out of that energy source will completely deenergize and deactivate the machine or equipment; (4) the machine or equipment is isolated from that energy source and locked out during servicing or maintenance; (5) a single lockout device will achieve a locker-out condition; (6) the lockout device is under the exclusive control of the authorized employee performing the servicing or maintenance; (7) the servicing or maintenance does not create hazards for other employees; and (8) the employer, in utilizing this exception, has had no accidents involving the unexpected activation or reenergization of the machine or equipment during servicing or maintenance.   (a)    Procedures were not developed, documented and utilized for the control of hazardous energy such as but not limited to; the electrical disconnect, the gravity and the movement of the flywheel on equipment such as but not limited to the Kurimoto C2F-2500W mechanical forging press located on lines such as but not limited to Line 4.  Employees performing servicing such as changing dies in equipment such as but not limited to; the C2F-2500W mechanical forging press located on lines such as but not limited to; Line 4 where employees were utilizing a safety interlock plug as isolation by removing the plug for control of each hazardous energy.  The TFO Tech Co., Ltd was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.147(c)(4)(i), which was contained in OSHA inspection number 507958, citation number 01, item number 002 and was affirmed as a final order on October 10, 2013, with respect to a workplace located at 221 State St., Jeffersonville, OH  43128.
Recent events (3)
  • — F (R) $0
  • — C (R) $9900
  • — Z (R) $9900

1910.218 F01 I

Deleted Repeat Gravity 5 1 instance 4 exposed
Issued
Feb 4, 2014
Abate by
Mar 24, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.218(f)(1)(i): The power to the press shall be locked out.  (a)    On forgining lines such as but not limited to Line 4, the power (i.e. electrical disconnects) to forging equipment such as but not limited to; the Kurimoto C2F-2500W forging press was not locked out by employees performing dies changes.  The TFO Tech Co., Ltd was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.218(f)(1)(i), which was contained in OSHA inspection number 507958, citation number 1, item number 9 and was affirmed as a final order on October 10, 2012, with respect to a workplace located at 221 State St., Jeffersonville, OH  43128.
Recent events (3)
  • — F (R) $0
  • — C (R) $0
  • — Z (R) $0

1910.147 C07 I A

Repeat Gravity 5 1 instance 4 exposed
Issued
Feb 4, 2014
Abate by
Mar 24, 2014
Penalty
Initial $9,900 · Current $5,000 Reduced
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.    (a)    Each employee performing servicing such as but not limited to changing dies on equipment such as but not limited to the Kurimoto C2F-2500W mechanical forging press were not trained on the method and means of shutdown and locking out the forging presses.  Employees were trained to use the removal of a safety plug as lockout.      The TFO Tech Co., Ltd was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.147(c)(7)(i)(A), which was contained in OSHA inspection number 507958, citation number 1, item number 5 and was affirmed as a final order on October 10, 2012, with respect to a workplace located at 221 State St., Jeffersonville, OH  43128.
Recent events (3)
  • — F (R) $5000
  • — C (R) $9900
  • — Z (R) $9900

1910.178 L02 II

Serious Gravity 5 2 instances 2 exposed
Issued
Feb 4, 2014
Abate by
Apr 24, 2014
Penalty
Initial $9,900 · Current $4,500 Reduced
29 CFR 1910.178(l)(2)(ii): The employer did not ensure that each operator had successfully completed the training consisting of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace.    (a)    TFO Tech did not ensure that each employees (temporary) operating powered industrial trucks at their location had completed training consisting of formal instruction and practicial training in that temporary workers were receiving their classroom training in the form of a generic test done by Remedy Intellegent Staffing.  The practical training being done by TFO employees was not adequate in that the evaluations dates of the evaluations were missing on some of the practical forklift evaluations, one evaluation was not filled out and checkmarks were being done consistently for the yes box on the evaluation regardless of the questions.    The TFO Tech Co., Ltd. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.178(l)(2)(ii), which was contained in OSHA inspection number 507958, citation number 01, item number 007 and was affirmed as a final order on 10/10/12, with respect to a workplace located at 221 State St., Jeffersonville, OH  43128.
Recent events (3)
  • — F (S) $4500
  • — C (R) $9900
  • — Z (R) $9900

1910.218 J03

Deleted Repeat Gravity 5 1 instance 4 exposed
Issued
Feb 4, 2014
Penalty
Initial $7,920 · Current $0 Reduced
29 CFR 1910.218(j)(3): Conveyors. Conveyor power transmission equipment shall be guarded in accordance with ANSI B20.1-1957, Safety Code for Conveyors, Cableways, and Related Equipment, which is incorporated by reference as specified in Sec. 1910.6.  (a)    The chain and sprocket located on the inside of Line 4 for the conveyor for the hub scrap was not guarded.  The TFO Tech co., Ltd was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.218(j)(3), which was contained in OSHA inspection number 507958, citation number 01, item number 10 and was affirmed as a final order on October 10, 2012, with respect to a workplace located at 221 State St., Jeffersonville, OH 43128.
Recent events (3)
  • — F (R) $0
  • — C (R) $7920
  • — Z (R) $7920

View TFO Tech CO., LTD's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339303042.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.