OSHA Inspection: KEATS MANUFACTURING CO.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of KEATS MANUFACTURING CO. in 350 W. HOLBROOK DR., WHEELING, IL 60090 (NAICS 332618). OSHA activity number 339303539.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Keats Manufacturing CO. for free Get an email when a new federal OSHA severe-injury report for Keats Manufacturing CO. is published. One employer, no account, unsubscribe in one click.
Site address
350 W. HOLBROOK DR.
City
WHEELING
State
IL
ZIP
60090
Mailing
350 W. HOLBROOK DR., WHEELING, IL 60090
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332618
Employees
95
Ownership type
Private (A)

5 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 6, 2013
Abate by
Dec 4, 2013
Penalty
Initial $2,975 · Current $1,650 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding were not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:       a) Production Area - The employer had a Peerless horizontal metal cutting band saw model #HB1118B, serial number #403117, that did not have the unused portion of the blade guarded on the left hand side facing the saw.
Recent events (2)
  • · I (S) $1650
  • · Z (S) $2975

1910.217 C02 I A

Serious Gravity 5 3 instances 3 exposed
Issued
Nov 6, 2013
Abate by
Dec 4, 2013
Penalty
Initial $2,975 · Current $1,665 Reduced
29 CFR 1910.217(c)(2)(i)(a): Point of operation on mechanical power press did not prevent entry of hands or fingers into the point of operation by reaching through, over, under or around the guard:     a) Punch Press Department - The point of operation on the Minster B1-32-01, mechanical power press serial #B1-32-11516, was not completely guarded.  The enclosure guard had openings on the front of the guard, left hand side, and a portion on the left hand side of the top of the guard.      b) Punch Press Department - The point of operation on the Minster B1-32-02, mechanical power press serial #B1-32-9556, was not completely guarded.  The enclosure guard had openings on the top portion of the guard.     c) Punch Press Department - The point of operation on the Minster B1-15-02, mechanical power press serial #B1-15-11881, was not completely guarded.  The guard had openings on the top and the right hand side.
Recent events (2)
  • · I (S) $1665
  • · Z (S) $2975

1910.217 C02 I D

Serious Gravity 5 1 instance 4 exposed
Issued
Nov 6, 2013
Abate by
Dec 4, 2013
Penalty
Initial $2,975 · Current $1,685 Reduced
29 CFR 1910.217(c)(2)(i)(d): Point of operation guard(s) on mechanical power press(es) did not utilize fasteners and/or the fasteners supplied were readily removable by the operator, so as to create the possibility of misuse or removal of essential parts:     a) Mechanical Press Department- The employer had a part revolution mechanical press Minster B1-15 #02, serial number B1-15-11881, that had the front guard with a metal fastener that could be easily opened by an operator.
Recent events (2)
  • · I (S) $1685
  • · Z (S) $2975

1910.157 C01

Other-than-serious 1 instance 4 exposed
Issued
Nov 6, 2013
Abate by
Dec 4, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1):  The employer had portable fire extinguishers that were not mounted, located, identified and readily accessible to employees without subjecting the employees to possible injury:     a) Shop Table Area - An ABC fire extinguisher placed on top of a table was blocked by a wrapped equipment and not readily accessible.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.303 B02

Other-than-serious 1 instance 4 exposed
Issued
Nov 6, 2013
Abate by
Dec 4, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled equipment were not used or installed in accordance with any instructions included in the listing or labeling:        a) Production Area - A power strip used to power a meter was not used or installed in accordance with any instructions included in the listing or labeling.