Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: ABCO STEEL, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ABCO STEEL, INC. in 643 W 138TH STREET, GLENPOOL, OK 74033 (NAICS 332710). OSHA activity number 339306250.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Abco Steel, INC. for free Get an email when a new federal OSHA severe-injury report for Abco Steel, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
ABCO STEEL, INC.
Site address
643 W 138TH STREET
City
GLENPOOL
State
OK
ZIP
74033
Mailing
PO BOX 249, GLENPOOL, OK 74033
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
14
Ownership type
Private (A)

2 citations on file for this inspection.

1910.178 L01 I

Serious Gravity 10 11 instances 12 exposed
Issued
Nov 19, 2013
Abate by
Nov 21, 2013
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):   On or about August 15, 2013, and at times prior thereto,  the employer did not ensure the ten (10) employees authorized to drive forklifts had received safe operation training.  Employees were exposed to the hazard of being struck by the forklift or crushed by a falling load.
Recent events (2)
  • · I (S) $1680
  • · Z (S) $2800

1910.303 G01

Serious Gravity 1 1 instance 12 exposed
Issued
Nov 19, 2013
Abate by
Nov 21, 2013
Penalty
Initial $1,200 · Current $720 Reduced
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  On or about August 15, 2012, the employer did not assure sufficient access was provided to electrical panel box.  Employee(s) were exposed to the hazard of electrical shock.
Recent events (2)
  • · I (S) $720
  • · Z (S) $1200

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339306250.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.