KANSAS CITY, MO —
OSHA Inspection: MULTIVAC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MULTIVAC in 11021 NORTH POMONA AVENUE, KANSAS CITY, MO 64153 (NAICS 326112). OSHA activity number 339307480.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MULTIVAC
- Site address
- 11021 NORTH POMONA AVENUE
- City
- KANSAS CITY
- State
- MO
- ZIP
- 64153
- Mailing
- 11021 NORTH POMONA AVENUE, KANSAS CITY, MO 64153
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326112
- Employees
- 3000
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.179 J02
- Issued
- Aug 30, 2013
- Abate by
- Sep 19, 2013
- Penalty
- Initial $3,000 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.179(j)(2). Overhead cranes were not inspected for defects on a daily basis for items including but not limited to; all functional operating mechanisms for maladjustment, deterioration or leakage of air or hydraulic systems. (a) On or about August 15, 2013 at 11021 N. POMONA AVENUE Kansas City Missouri 64153 , employees in the machine shop, manufacturing and production area were exposed to a struck by hazard from possible failure of overhead cranes because monthly inspections for abnormalities were not accomplished or documented.
Recent events (2)
- — I (S) $2100
- — Z (S) $3000
1910.179 J02 III
- Issued
- Aug 30, 2013
- Abate by
- Oct 18, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(j)(2)(iii): A certification record which includes the date of inspection, the signature of the person who performed the inspection and the serial number, or other identifier, of the hook inspected, was not maintained. On, or about August 15, 2013, employees in the machine shop, manufacturing and production area were exposed to a struck by hazard from possible failure of load hooks because monthly inspections for deformities or cracks were not accomplished or documented.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.179 J02 IV
- Issued
- Aug 30, 2013
- Abate by
- Sep 19, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(j)(2)(iv): Monthly inspections of hoist chains, with a certification record which includes the date of inspection, the signature of the person who performed the inspection and an identifier of the chain which was inspected, were not performed. (a) On, or about August 15, 2013, employees in the machine shop, manufacturing and production area were exposed to a struck by hazard from possible failure of hoist chains because monthly inspections for deformities or cracks were not accomplished or documented.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A03 II
- Issued
- Aug 30, 2013
- Abate by
- Sep 19, 2013
- Penalty
- Initial $7,000 · Current $4,900 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii). Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s). (a) On or about August 15, 2013, at 11021 N. Pomona Kansas City Missouri, 64089, employees in the manufacturing shop area were exposed to a hazard from a grinder wheel. The wheel was worn to the point there was a one and a half inch gap between the grinder wheel and the attached guard.
Recent events (2)
- — I (S) $4900
- — Z (S) $7000
1910.303 G01 I
- Issued
- Aug 30, 2013
- Abate by
- Sep 26, 2013
- Penalty
- Initial $4,000 · Current $2,800 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(i): Sufficient access and working space was not provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment. (a) On, or before August 15, 2013 at 11021 N Pomona Kansas City, Missouri 64089, Employees were exposed to an electrical hazard in the auxiliary demonstration room, due to failure to maintain adequate working space in front of the electrical circuit breaker box which was blocked by a collection of miscellaneous supplies piled in front of the area.
Recent events (2)
- — I (S) $2800
- — Z (S) $4000
1910.303 G02 I
- Issued
- Aug 30, 2013
- Abate by
- Sep 26, 2013
- Penalty
- Initial $5,000 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures. (a) On, or before, August 15, 2013 at 11021 N. POMONA AVENUE Kansas City Missouri 64153 in the axillary demonstration room employees were exposed to electrical hazard from a 120 volt Vulcan Cardinal refrigerator with no protection from exposed conductors.
Recent events (2)
- — I (S) $3500
- — Z (S) $5000
1910.304 G05
- Issued
- Aug 30, 2013
- Abate by
- Sep 19, 2013
- Penalty
- Initial $3,000 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective. (a) On or about August 15, 2013, at 11021 N. Pomona Kansas City Missouri, 64089, employees in demonstration room were exposed to a hazard from a refrigerator used daily, due to a damaged electrical plug with a missing ground prong connection.
Recent events (2)
- — I (S) $2100
- — Z (S) $3000
1910.305 G02 III
- Issued
- Aug 30, 2013
- Abate by
- Sep 19, 2013
- Penalty
- Initial $3,000 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws. (a) On or about August 15, 2013, at 11021 N. Pomona Kansas City Missouri, 64089. ThePBI Dansensor machine did not have adequate strain relief at the plug-in end there was not adequate insulation as the insulation had pulled back exposing interior wiring.
Recent events (2)
- — I (S) $2100
- — Z (S) $3000
More inspections at Multivac
View Multivac's full OSHA safety record →
More inspections in this industry (NAICS 326112)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339307480.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.