SPRING, TX —
OSHA Inspection: SIXTO MARTINEZ
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SIXTO MARTINEZ in 3510 GALLEY MIST, SPRING, TX 77388 (NAICS 238140). OSHA activity number 339308272.
Where did this inspection happen?
- Establishment
- SIXTO MARTINEZ
- Site address
- 3510 GALLEY MIST
- City
- SPRING
- State
- TX
- ZIP
- 77388
- Mailing
- 4279 HAMBLEDON VILLAGE, HOUSTON, TX 77014
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 9
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 B01 I
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $960.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary. The employer does not ensure each platform unit is installed so that the space between adjacent units is no more than 1 inch. This violation was observed on or about August 9, 2013, on the exterior west side of the single family dwelling where employees were exposed to an approximately 6 ft 8 inch fall hazard when performing masonry work from fabricated frame scaffolding without the gap between planks being less than one inch. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that each platform unit is installed so that the space between adjacent units and the space between the platform and uprights are no more than 1 inch wide.
Recent events (2)
- — I (S) $960
- — Z (S) $1600
1926.451 B04
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $960.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(4): Each end of a platform, not cleated or otherwise restrained by hooks or equivalent means, did not extend over the centerline of its support at least 6 inches (15 cm): The employer does not ensure each end of a platform, not cleated does not extend over the centerline of its support at least 6 inches. This violation was observed on or about August 9, 2013, on the exterior west side of the single family dwelling where employees were exposed to an approximately 6 ft 8 inch fall hazard when performing masonry work from fabricated frame scaffolding without the planking being cleated or extended over end at least 6 inches. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that each platform , not cleated or otherwise restrained by hooks or equivalent means, extend over the centerline of its support by at least 6 inches.
Recent events (2)
- — I (S) $960
- — Z (S) $1600
1926.451 C02
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $960.00 Reduced
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: The employer does not ensure each supported scaffold poles bear on base plate and mud sills. This violation was observed on or about August 9, 2013, on the exterior west side of the single family dwelling where employees were exposed to an approximately 6 ft 8 inch fall hazard when performing masonry work from fabricated frame scaffolding without base plates installed. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that supported scaffold poles, legs, posts, frames, and uprights bear on base plates and mud sills or other adequate firm foundation.
Recent events (2)
- — I (S) $960
- — Z (S) $1600
1926.451 E01
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $960.00 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. The employer does not ensure each scaffold platform 2 feet or more are provided with access. This violation was observed on or about August 9, 2013, on the exterior west side of the single family dwelling where employees were exposed to an approximately 6 ft 8 inch fall hazard when performing masonry work from fabricated frame scaffolding without a point of access or other type of ladder. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that each scaffold platform 2 feet or more above or below an a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface is used as a means of access.
Recent events (2)
- — I (S) $960
- — Z (S) $1600
1926.452 C02
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $960.00 Reduced
General-duty citation text
29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally: The employer does not ensure each tubular welded frames and panels are braced by cross, horizontal, or diagonal braces. This violation was observed on or about August 9, 2013, on the exterior west side of the single family dwelling where employees were exposed to an approximately 6 ft 8 inch fall hazard when performing masonry work from fabricated frame scaffolding without the gap between planks being less than one inch. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that each tubular welded frames and panels are braced by cross, horizontal, or diagonal braces, or combination thereof, which would secure vertical members together laterally.
Recent events (2)
- — I (S) $960
- — Z (S) $1600
More inspections in this industry (NAICS 238140)
RENO, NV—2026-07-16
DC MASONRY
WINNETKA, IL—2026-07-15
CHICAGO STUCCO CO.
LODI, NJ—2026-07-15
J & O MASONRY CONTRACTORS
DORAVILLE, GA—2026-07-14
SUDLOW CONCRETE, INC.
FLAGLER BEACH, FL—2026-07-14
PLANET DESIGN SERVICES, INC.
More inspections in TX
WICHITA FALLS, TX—2026-07-16
UNITED RENTALS, INC.
SAN MARCOS, TX—2026-07-16
CASA MECHANICAL SERVICES, LTD.
CLARKSVILLE, TX—2026-07-15
SEQUOIAS TREE EXPERT LLC
EL PASO, TX—2026-07-15
SURE STEEL
CORPUS CHRISTI, TX—2026-07-15
NORTH STAR ENERGY SOLUTIONS LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339308272.