TAMUNING, GU —
OSHA Inspection: SUMITOMO MITSUI CONSTRUCTION CO.,LTD.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SUMITOMO MITSUI CONSTRUCTION CO.,LTD. in SAN VITORES RD, TAMUNING, GU 96913 (NAICS 236220). OSHA activity number 339310831.
Where did this inspection happen?
- Establishment
- SUMITOMO MITSUI CONSTRUCTION CO.,LTD.
- Site address
- SAN VITORES RD
- City
- TAMUNING
- State
- GU
- ZIP
- 96913
- Mailing
- P.O. BOX 9670, TAMUNING, GU 96931
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.451 B01
- Issued
- Penalty
- Initial $2380.00 · Current $1190.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) a. "Eggs and Things" construction project, interior scaffolding - Noted on or about 8/14/13 and at times prior thereto, the interior scaffolding was not fully planked on both the left and right sides. The right side had a gap measuring aprroximately 2.5 ft. x 6 ft. thereby exposiing employees to a fall hazard over 5 ft. The left side had a measured gap of approximately 9 in. x 6 ft.
Recent events (2)
- — I (S) $1190
- — Z (S) $2380
1926.452 C02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally: a. "Eggs and Things" construction project, interior scaffolding - Noted on or about 8/14/13 and at times prior thereto, a front, central section of scaffold framework was not erected with cross bracing. The missing cross brace would cause the scaffold to be less stable under load.
Recent events (1)
- — Z (S) $0
More inspections at SUMITOMO MITSUI CONSTRUCTION CO.,LTD.
BARRIGADA, GU—2026-01-16
SUMITOMO MITSUI CONSTRUCTION CO. LTD.
TAMUNING, GU—2025-05-21
SUMITOMO MITSUI CONSTRUCTION CO. LTD.
TAMUNING, GU—2024-10-30 00:00:00
SUMITOMO MITSUI CONSTRUCTION CO. LTD.
TAMUNING, GU—2024-05-03 00:00:00
SUMITOMO MITSUI CONSTRUCTION CO. LTD.
TAMUNING, GU—2023-10-13 00:00:00
SUMITOMO MITSUI CONSTRUCTION CO. LTD.
View SUMITOMO MITSUI CONSTRUCTION CO.,LTD.'s full OSHA safety record →
More inspections in this industry (NAICS 236220)
IRVINE, CA—2026-07-13
SNEARY CONSTRUCTION, INC.
IRVINE, CA—2026-07-13
KUKBO DESIGN USA LLC
SIOUX FALLS, SD—2026-07-13
REM CONSTRUCTION SERVICES, LLC
INDIAN ROCKS BEACH, FL—2026-07-10
UNKNOWN CONTRACTOR
SIOUX FALLS, SD—2026-07-10
HENRY CARLSON COMPANY
More inspections in GU
BARRIGADA, GU—2026-01-22
DURI CORPORATION
TAMUNING, GU—2026-01-21
DLR CORPORATION
BARRIGADA, GU—2026-01-21
DURI CORPORATION
TAMUNING, GU—2026-01-20
MG CONSTRUCTION COMPANY
BARRIGADA, GU—2026-01-20
PFM -VERTEX-LMS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339310831.