CHEROKEE, OK ·
OSHA Inspection: MACKELLAR SERVICES, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MACKELLAR SERVICES, INC. in UNMARKED WELL SITE NEAR HWY 11 & E0100, CHEROKEE, OK 73728 (NAICS 211111). OSHA activity number 339322836.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MACKELLAR SERVICES, INC.
- Site address
- UNMARKED WELL SITE NEAR HWY 11 & E0100
- City
- CHEROKEE
- State
- OK
- ZIP
- 73728
- Mailing
- P.O. BOX 18298, OKLAHOMA CITY, OK 73117
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 211111
- Employees
- 5
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1910.23 C01
- Issued
- Jan 22, 2014
- Abate by
- Jan 28, 2014
- Penalty
- Initial $2,800 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floor(s) or platform(s) 4 feet or more above the adjacent floor or ground level were not guarded by a standard railing on all open sides: At the worksite: On or about August 19, 2013, the employer did not have a guard railing on the rig platform when the height was greater than four feet. Employees were exposed to fall from height hazards.
Recent events (2)
- · I (S) $2000
- · Z (S) $2800
1910.24 B
- Issued
- Jan 22, 2014
- Abate by
- Jan 28, 2014
- Penalty
- Initial $2,100 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.24(b): Fixed stairs were not provided for access from one structure level to another where operations necessitate regular travel between levels, and for access to operating platforms at any equipment which requires attention routinely during operations. Fixed stairs shall also be provided where access to elevations is daily or at each shift for such purposes as gauging, inspection, regular maintenance, etc., where such work may expose employees to acids, caustics, gases, or other harmful substances, or for which purposes the carrying of tools or equipment by hand is normally required: At the worksite: On or about August 19, 2013, the employer did not have a fixed stairs from the ground level to the operators station. Employees were exposed to fall from height hazards.
Recent events (2)
- · I (O) $1200
- · Z (S) $2100
1910.36 B01
- Issued
- Jan 22, 2014
- Abate by
- Jan 28, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.36(b)(1): At least two exit routes were not available in a workplace to permit prompt evacuation of employees and other building occupants during an emergency: At the worksite: On or about August 19, 2013, the employer did not have two means of exit from the rig platform in the event of an emergency. Employees were exposed to fire and explosion hazards.
Recent events (2)
- · I (O) $0
- · Z (S) $0
1910.176 B
- Issued
- Jan 22, 2014
- Abate by
- Jan 24, 2014
- Penalty
- Initial $2,800 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.176(b): Storage of materials created a hazard. Bags, containers, bundles, etc., stored in tiers were not stacked, blocked, interlocked and limited in height so that they were stable and secure against sliding or collapsing: At the worksite: On or about August 19, 2013, the employer did not have the pipe on the pipe rack chocked or block to prevent shifting. Employees were exposed to struck-by and caught in between hazards.
Recent events (2)
- · I (O) $1200
- · Z (S) $2800
1910.157 C04
- Issued
- Jan 22, 2014
- Abate by
- Jan 27, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(4): The employer did not assure that portable fire extinguishers were maintained in a fully charged and operable condition and kept in their designated places at all times except during use: At the worksite: On or about August 19, 2013, the employer did not maintain a portable fire extinguisher fully charged on a service rig. Employees were exposed to fire hazards.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 211111)
More inspections in OK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339322836.