Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: AIR INNOVATIONS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of AIR INNOVATIONS in 7000 PERFORMANCE DRIVE, NORTH SYRACUSE, NY 13212 (NAICS 333415). OSHA activity number 339323438.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch AIR Innovations for free Get an email when a new federal OSHA severe-injury report for AIR Innovations is published. One employer, no account, unsubscribe in one click.
Establishment
AIR INNOVATIONS
Site address
7000 PERFORMANCE DRIVE
City
NORTH SYRACUSE
State
NY
ZIP
13212
Mailing
7000 PERFORMANCE DRIVE, NORTH SYRACUSE, NY 13212
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333415
Employees
38
Ownership type
Private (A)

9 citations on file for this inspection.

1910.212 A01

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 20, 2013
Abate by
Oct 2, 2013
Penalty
Initial $1,785 · Current $2,400
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by rotating parts:    a)  RGA Area, on or about 8/20/13:  Rotating chuck on a Central Machinery drill press was not guarded.    Abatement certification must be submitted for this item.
Recent events (3)
  • · J (S) $2400
  • · C (S) $1785
  • · Z (S) $1785

1910.212 B

Serious Gravity 1 2 instances 2 exposed
Issued
Sep 20, 2013
Abate by
Oct 25, 2013
Penalty
Initial $1,785 · Current $0 Reduced
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:    a)  Advanced Air Area, on or about 8/20/13:  A Delta pedestal grinder was not secured to prevent walking or moving.    b)  Wine Work Cell, on or about 8/20/13:  A Baldor pedestal grinder was not secured to prevent walking or moving.    Abatement certification must be submitted for these items.
Recent events (3)
  • · J (S) $0
  • · C (S) $1785
  • · Z (S) $1785

1910.213 H01

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 20, 2013
Abate by
Oct 10, 2013
Penalty
Initial $2,380 · Current $0 Reduced
29 CFR 1910.213(h)(1): The sides of the lower exposed portion of the blade of radial saw(s) were not guarded to the full diameter of the blade by a device that automatically adjusted itself to the thickness of the stock and remained in contact with the material being cut:      a)  Packaging Area, on or about 8/20/13:  The lower blade guard for the left side of a Sears Craftsman radial arm saw was jammed up out of position and would not automatically adjust.    Abatement certification must be submitted for this item.
Recent events (3)
  • · J (S) $0
  • · C (S) $2380
  • · Z (S) $2380

1910.215 A04

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Sep 20, 2013
Abate by
Oct 2, 2013
Penalty
Initial $1,785 · Current $0 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:  a)  Wine Work Cell, on or about 8/20/13:  The work rest on a Baldor pedestal grinder was not adjusted to 1/8" from the wheel.  Abatement certification must be submitted for this item.
Recent events (3)
  • · J (S) $0
  • · C (S) $1785
  • · Z (S) $1785

1910.215 B09

Deleted Serious Gravity 1 2 instances 1 exposed
Issued
Sep 20, 2013
Abate by
Oct 2, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  a)  Advanced Air Area, on or about 8/20/13:  Tongue guard for the left grinding wheel on a Delta pedestal grinder measured 1 1/2 inches away.  b)  Wine Work Cell, on or about 8/20/13:  Tongue guard for the left grinding wheel on a Baldor pedestal grinder measured one inch away.  Abatement certification must be submitted for these items.
Recent events (3)
  • · J (S) $0
  • · C (S) $0
  • · Z (S) $0

1910.304 G05

Serious Gravity 1 2 instances 1 exposed
Issued
Sep 20, 2013
Abate by
Oct 25, 2013
Penalty
Initial $1,785 · Current $1,785
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:  a)  Advanced Air Area, on or about 8/20/13:  Two duplex receptacle outlets along a workbench were not grounded.  Abatement certification must be submitted for this item.
Recent events (3)
  • · J (S) $1785
  • · C (S) $1785
  • · Z (S) $1785

1910.305 G01 IV A

Serious Gravity 1 5 instances 2 exposed
Issued
Sep 20, 2013
Abate by
Oct 25, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a)  Shipping/Receiving Area, on or about 8/20/13:  An extension cord for a bug zapper was strung overhead and being used as permanent wiring.  b)  Shipping/Receiving Area, on or about 8/20/13:  A strip outlet being used for charging screw gun batteries was being used as permanent wiring.  c)  RGA Area, on or about 8/20/13:  A blue extension cord providing current to a Wells horizontal bandsaw was being used as permanent wiring.  d)  Advanced Air Area, on or about 8/20/13:  An orange extension cord providing current to a belt sander and a bandsaw was being used as permanent wiring.  e)  Advanced Air Area, on or about 8/20/13:  A flexible cord plugged into a four way receptacle outlet on the floor providing current to several outlets along two workbenches was being used as permanent wiring.   f)  Wine Work Cell, on or about 8/20/13:  A strip outlet being used for charging batteries for portable tools was being used as permanent wiring.  Abatement certification must be submitted for these items.
Recent events (3)
  • · J (S) $0
  • · C (S) $0
  • · Z (S) $0

1910.305 G02 III

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 20, 2013
Abate by
Oct 25, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  a)  Advanced Air Area, on or about 8/20/13:  A flexible cord providing current to outlets along a workbench was pulled loose at the plug fitting and not provided with strain relief.  Abatement certification must be submitted for this item.
Recent events (3)
  • · J (S) $0
  • · C (S) $0
  • · Z (S) $0

1910.334 A02 I

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 20, 2013
Abate by
Oct 2, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  a)  Advanced Air Area, on or about 8/20/13:  A flexible cord providing current to a four way receptacle outlet had damage to the outer jacket.  Abatement certification must be submitted for this item.
Recent events (3)
  • · J (S) $0
  • · C (S) $0
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339323438.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.