WASHINGTON, DC —
OSHA Inspection: SIGNATURE COLLISION CENTER
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of SIGNATURE COLLISION CENTER in 1355 E STREET SE, WASHINGTON, DC 20003 (NAICS 811121). OSHA activity number 339326795.
Where did this inspection happen?
- Establishment
- SIGNATURE COLLISION CENTER
- Site address
- 1355 E STREET SE
- City
- WASHINGTON
- State
- DC
- ZIP
- 20003
- Mailing
- 1355 E STREET SE, WASHINGTON, DC 20003
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811121
- Employees
- 11
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.132 A
- Issued
- Penalty
- Initial $3500.00 · Current $2625.00 Reduced
General-duty citation text
29 CFR 1910.132(a): Protective equipment was not used as necessary whenever hazards capable of causing injury and impairment were encountered: (a) Paint Shop - A body man was observed not wearing eye protection while being exposed to eye injury hazards of flying particles and dust coming from operating an electrical powered sander to smooth body filler on an automobile, on or about 8/29/2013.
Recent events (2)
- — I (S) $2625
- — Z (S) $3500
1910.134 E01
- Issued
- Abate by
- Penalty
- Initial $2100.00 · Current $1575.00 Reduced
9015
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator before the employee was fit tested or required to use the respirator in the workplace: (a) Garage - A painter provided with and required to use a 3M model half-face model respirator while conducting auto body painting operations was not provided a medical evaluation by the employer, on or about 8/25/2013. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $1575
- — Z (S) $2100
1910.305 B01 II
- Issued
- Penalty
- Initial $3500.00 · Current $2625.00 Reduced
8870
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: (a) Garage - A painter was exposed to electrical hazards while tripping a 240 voltage supplied circuit located in an electrical panel box containing spaces that were not covered or enclosed, on or about 8/20/2013.
Recent events (2)
- — I (S) $2625
- — Z (S) $3500
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2100.00 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement and maintain at the workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g) and (h) of this section for labels and other forms of warning, material safety data sheets, and employee information and training will be met: (a) Garage - Body Men performing auto body repair operations were not informed and trained on the hazards in using hazardous chemical products including but limited to Evercoat Z-Grip Body Filler, a product containing styrene, on or about 8/20/2013. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $2100
- — Z (S) $2800
1910.1200 G01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(g)(1): The employer did not have a material safety data sheet for each hazardous chemical in use: (a) Garage - Safety Data Sheets were not maintained at the worksite for hazardous chemical products including Evercoat Z-Grip Body Filler, a chemical product using regularly by employees conducting auto body repair operations, on or about 8/20/2013. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 H01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(h)(1): The employer did not provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new physical or health hazard the employees had not previously been trained about was introduced into their work area: (a) Garage - Employees conducting auto repair operations were not informed and trained on the hazards in their using Evercoat Z-Grip Body Filler, a product containing the hazardous chemical styrene , on or about 8/25/2013. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 C01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
9015
General-duty citation text
29 CFR 1910.134(c)(1): The employer did not establish and implement a written respiratory protection program with worksite-specific procedures in any workplace where respirators are necessary to protect the health of the employee or whenever respirators are required by the employer: (a) Garage - Employees provided with and required by the employer to wear respirators while conducting various operations, including but not limited to, painting, mechanical and auto body repair had not been provided the elements of a respiratory program as required, on or about 8/20/2013. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 C02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
9015
General-duty citation text
29 CFR 1910.134(c)(2): Respirator users were not provided with the information contained in Appendix D to this section when the employer determined that any voluntary respirator use was permissible: (a) Garage - Employees provided with and permitted by the employer to wear 3M N95 filtering facepiece respirators while conducting various operations, including but not limited to, mechanical and auto body repair, had not been provided the Appendix D information as required, on or about 8/20/2013. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 F01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
9015
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employees using a tight-fitting facepiece respirator pass an appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT) as stated in this paragraph: (a) Garage - A painter provided with and required to use a 3M half-face model respirator while conducting auto body painting operations was not provided a fit test by the employer, on or about 8/20/2013. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 K03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
9015
General-duty citation text
29 CFR 1910.134(k)(3): Training was not provided prior to requiring employees to use a respirator in the workplace: (a) Garage - A painter provided with and required to use a 3M half-face model respirator was being exposed to hazardous chemicals while conducting auto body painting operations had not been provided respirator triaining by the employer, on or about 8/25/2013. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 811121)
SUMMIT, IL—2026-07-08
BUDS BODY SHOP SUPPLY & PAINT
PUYALLUP, WA—2026-07-08
WA317991990 - GLASS WORKS PRO INC
SALEM, VA—2026-07-08
CERTIFIED COLLISION REPAIR
TUMWATER, WA—2026-07-07
WA317991940 - EMERGENCY VEHICLE SOLUTIONS LLC
ASHLAND, OR—2026-06-26
317744632 - HINKS ENTERPRISES INC
More inspections in DC
WASHINGTON, DC—2026-06-30
U.S. DEPARTMENT OF AGRICULTURE
WASHINGTON, DC—2026-06-16
MACY'S
WASHINGTON, DC—2026-06-02
RIGO MULTISERVICES
WASHINGTON, DC—2026-06-02
DDC CPL LLC
WASHINGTON, DC—2026-06-02
DDC CPL LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339326795.