MONROE TOWNSHIP, NJ ·
OSHA Inspection: A. SANTINI MOVING & STORAGE CO.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of A. SANTINI MOVING & STORAGE CO. in 6A FITZGERALD, MONROE TOWNSHIP, NJ 08831 (NAICS 484210). OSHA activity number 339328635.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- A. SANTINI MOVING & STORAGE CO.
- Site address
- 6A FITZGERALD
- City
- MONROE TOWNSHIP
- State
- NJ
- ZIP
- 08831
- Mailing
- 6A FITZGERALD, MONROE TOWNSHIP, NJ 08831
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 484210
- Employees
- 45
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
1910.176 A
- Issued
- Dec 2, 2013
- Abate by
- Dec 12, 2013
- Penalty
- Initial $2,975 · Current $2,083 Reduced
General-duty citation text
29 CFR 1910.176(a): Aisle(s) or passageway(s) were not kept clear where mechanical handling equipment was used: a/ ASantini/Monroe Township NJ Site: Warehouse. Aisle between storage racks X and Y was not maintained clear of storage, e.g., boxes of product. Observed on/or about 8/20/2013
Recent events (2)
- · I (S) $2083
- · Z (S) $2975
1910.176 B
- Issued
- Dec 2, 2013
- Abate by
- Jan 21, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.176(b): Material stored in tiers was not stable and secure: a/ ASantini/Monroe Township NJ Site: Warehouse. Storage racks with damage had not been replaced and were being used while waiting for new racks to arrive. Observed on/or about 8/20/2013.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.178 A05
- Issued
- Dec 2, 2013
- Abate by
- Dec 27, 2013
- Penalty
- Initial $2,380 · Current $1,666 Reduced
General-duty citation text
29 CFR 1910.178(a)(5): Nameplates or markings for powered industrial trucks that were equipped with front-end attachments other than factory installed attachments, the user did not request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered: a/ ASantini/Monroe Township NJ Site: Warehouse. Forklift truck(s) used with a rug pole attachment that was not installed by the manufacturer was not rated and labeled to include the weight capacity of rug pole. Observed on/or about 8/20/2013
Recent events (2)
- · I (S) $1666
- · Z (S) $2380
1910.178 K01
- Issued
- Dec 2, 2013
- Abate by
- Dec 27, 2013
- Penalty
- Initial $2,380 · Current $1,666 Reduced
General-duty citation text
29 CFR 1910.178(k)(1): The brakes of highway trucks(s) were not set and wheel chocks placed under the rear wheels to prevent truck from rolling: a/ ASantini/Monroe Township NJ Site: Warehouse Yard. Over the road trucks are not provided with chocks and/or a procedure is not in place to ensure chocks are used when required. Observed on/or about 8/20/2013.
Recent events (2)
- · I (S) $1666
- · Z (S) $2380
1910.110 D10
- Issued
- Dec 2, 2013
- Abate by
- Dec 12, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.110(d)(10): Precautions were not taken to prevent damage to LP gas system(s) from vehicular traffic: a/ ASantini/Monroe Township NJ Site: Yard Shipping/Receiving Area: Storage area for Propane tanks used to power forklift equipment was not positioned so that they would not be struck by vehicle traffic. Observed on/or about 8/20/2013.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.303 G01 II
- Issued
- Dec 2, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(ii): Working space provided about electrical equipment rated 600 volts, nominal, or less was used for storage: a/ ASantini/Monroe Township NJ Site: Warehouse. Electrical panel boxes located near right of the main office were blocked by a Hyster forklift truck. (Standard voltage 480 Volts/3 phase) Observed on/or about 8/20/2013.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 484210)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339328635.