Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: FREEZER REFRIGERATED STORAGE, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of FREEZER REFRIGERATED STORAGE, INC. in 1429 BOULDER BOULEVARD, VALMEYER, IL 62295 (NAICS 493120). OSHA activity number 339335754.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Freezer Refrigerated Storage, INC. for free Get an email when a new federal OSHA severe-injury report for Freezer Refrigerated Storage, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1429 BOULDER BOULEVARD
City
VALMEYER
State
IL
ZIP
62295
Mailing
1429 BOULDER BOULEVARD, VALMEYER, IL 62295
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493120
Employees
65
Ownership type
A

6 citations on file for this inspection.

1910.37 A03

Serious Gravity 5 2 instances 65 exposed
Issued
Jan 29, 2014
Abate by
Jan 15, 2015
Penalty
Initial $2,520 · Current $1,638 Reduced
29 CFR 1910.37(a)(3): Exit routes were not free and unobstructed.  Materials and equipment were placed, either permanently or temporarily, within the exit route.       Employees performing materials handling in the following instances were exposed to restricted emergency egress hazards and the employer did not ensure exit routes were free and unobstructed.       1) Employees at the dock were unable to access the exit door due to a waste can in the exit route.       2) Employees in Room 3 were unable to access the exit door due to a pallet of product that was placed in the exit route.
Recent events (3)
  • · F (S) $1638
  • · C (S) $2520
  • · Z (S) $2520

1910.37 A04

Serious Gravity 5 2 instances 65 exposed
Issued
Jan 29, 2014
Abate by
Jan 15, 2015
Penalty
Initial $2,520 · Current $1,638 Reduced
29 CFR 1910.37(a)(4): Safeguards designed to protect employees during an emergency (e.g. sprinkler system, alarm system, fire doors, exit lighting) were not in proper working order at all times:       Employees performing materials handling in the following instances were exposed to restricted emergency egress hazards and the employer did not ensure exit lighting for the outside of the facility, however inside the underground structure, was in proper working order at all times.       1) Overhead lighting at exit route door 3 was not operational.       2) Overhead lighting at exit route door 2 was not operational.
Recent events (3)
  • · F (S) $1638
  • · C (S) $2520
  • · Z (S) $2520

1910.37 B01

Serious Gravity 5 2 instances 65 exposed
Issued
Jan 29, 2014
Abate by
Jan 15, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(1): Each exit route was not adequately lighted so that an employee with normal vision could see along the exit route:       Employees performing materials handling in the following instances were exposed to restricted emergency egress hazards and the employer did not ensure exit lighting for the outside of the facility, however inside the underground structure, was in proper working order at all times.       1) Overhead lighting at exit route door 3 was not operational.       2) Overhead lighting at exit route door 2 was not operational.
Recent events (3)
  • · F (S) $0
  • · C (S) $0
  • · Z (S) $0

1910.178 L01 II

Serious Gravity 5 1 instance 65 exposed
Issued
Jan 29, 2014
Abate by
Jan 15, 2015
Penalty
Initial $2,520 · Current $1,638 Reduced
29 CFR 1910.178(l)(1)(ii):  The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a power industrial truck:      Employees performing materials handling with forklifts were exposed to struck-by and caught between hazards and the employer did not ensure employees were trained to operate the forklifts either by completion of a training program or as permitted in paragraph (l)(5) of the section.
Recent events (3)
  • · F (S) $1638
  • · C (S) $2520
  • · Z (S) $2520

1910.36 D01

Willful Gravity 5 2 instances 65 exposed
Issued
Jan 29, 2014
Abate by
Jan 15, 2015
Penalty
Initial $39,600 · Current $25,740 Reduced
29 CFR 1910.36(d)(1): Employees were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge.      Employees performing materials handling in the following instances were exposed to restricted emergency egress hazards and the employer did not ensure exit route doors were able to be opened at all times without special knowledge or tools.      1) Employees in Room 3 were unable to open the exit route door due to the application of spray insulation foam which had sealed the exit route door closed.      2) Employees in Room 4 were unable to open the exit door without excessive force in that the door was sealed shut by ice formations on the outside.
Recent events (3)
  • · F (W) $25740
  • · C (W) $39600
  • · Z (W) $39600

1910.305 D02

Other-than-serious 3 instances 65 exposed
Issued
Jan 29, 2014
Abate by
Jan 15, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(d)(2): Panelboards were mounted in cabinets, cutout boxes, or enclosures designed for the purpose and were not dead front.  Panelboards other than the dead front externally-operable type were not exclusively permitted where accessible only to qualified persons:      Employees performing work in the dock were exposed to fire and electrical hazards and the employer did not ensure HVAC electrical cabinets were maintained in a dead front condition and allowed exposed electrical in a common area accessible to all personnel.
Recent events (3)
  • · F (O) $0
  • · C (O) $0
  • · Z (O) $0

View Freezer Refrigerated Storage, INC.'s full OSHA safety record →