Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: SNF LLC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of SNF LLC in 209 W HACKBERRY AVE, MCALLEN, TX 78501 (NAICS 623110). OSHA activity number 339350233.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch SNF LLC for free Get an email when a new federal OSHA severe-injury report for SNF LLC is published. One employer, no account, unsubscribe in one click.
Establishment
SNF LLC
Site address
209 W HACKBERRY AVE
City
MCALLEN
State
TX
ZIP
78501
Mailing
209 W HACKBERRY AVE, MCALLEN, TX 78501
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
623110
Employees
46
Ownership type
Private (A)

4 citations on file for this inspection.

1910.151 C

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 8, 2014
Penalty
Initial $2,550 · Current $1,530 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:   At this location, in the Laundry area, the flow from the nozzle of the emergency eye wash was not adequate.
Recent events (2)
  • · I (S) $1530
  • · Z (S) $2550

1910.305 A02 I B

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 8, 2014
Penalty
Initial $2,550 · Current $1,530 Reduced
29 CFR 1910.305(a)(2)(i)(B): Temporary wiring was used for a period exceeding 90 days:  At this location in the Medical Records office Room Four, the overhead fluorescent light was connected to an extension cord and was hanging down along the wall.
Recent events (2)
  • · I (S) $1530
  • · Z (S) $2550

1910.305 J01 I

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 8, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(j)(1)(i): Fixtures, lampholders, lamps, rosettes, and receptacles located within 8 feet of the floor had live parts exposed to employee contact:  At this location in the Medical Records Room Four, the overhead fluorescent light was not provided with a guard.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.141 D02 III

Other-than-serious 1 instance 1 exposed
Issued
Jan 8, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.141(d)(2)(iii): Lavatories were not provided with hand soap or similar cleansing agent:  At this location in employee restroom for the Rehabilitation Rooms five and six, hand soap was not provided.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339350233.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.