Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: CONNELL & SCHMIDT

Programmed Related inspection · Safety discipline

On , OSHA opened a programmed Related safety inspection of CONNELL & SCHMIDT in 1335 MARYLAND AVENUE, NE, WASHINGTON, DC 20002 (NAICS 236116). OSHA activity number 339352114.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Connell & Schmidt for free Get an email when a new federal OSHA severe-injury report for Connell & Schmidt is published. One employer, no account, unsubscribe in one click.
Establishment
CONNELL & SCHMIDT
Site address
1335 MARYLAND AVENUE, NE
City
WASHINGTON
State
DC
ZIP
20002
Mailing
817 L STREET, SE, WASHINGTON, DC 20003
Inspection type
Programmed Related (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236116
Employees
4
Ownership type
Private (A)

2 citations on file for this inspection.

1926.1052 C01 II

Serious Gravity 5 2 instances 4 exposed
Issued
Jan 24, 2014
Penalty
Initial $1,800 · Current $1,800
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stair rail system along each unprotected side or edge:   (a)  Front of Building - Subcontractor workers were observed using a stairway with 5 risers to access the building that was missing a stair rail and exposed to an impalement hazard, on or about August 22, 2013.   (b)  2nd Floor - Subcontractor workers were using a stairway with 16 risers to access their 3rd floor work area that was missing its stair rail on the unguarded open side, on or about August 22, 2013.   For the purposes of this inspection, the employer was determined to be the controlling employer of the jobsite. The employer is being cited under OSHA's Multi-Employer Workplace Policy.
Recent events (1)
  • · Z (S) $1800

1926.1052 C12

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 24, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.1052(c)(12): Unprotected sides and edges of stairway landings were not provided with guardrail systems that meet the criteria contained in Subpart M of 29 CFR 1926:   (a)  Front of Building - Subcontractor's workers were observed using a stairway with 5 risers to access the building that had a landing with a guardrail system missing its mid-rail and the workers were exposed to an 8 feet fall hazard, on or about August 22, 2013.   For the purposes of this inspection, the employer was determined to be the controlling employer of the jobsite. The employer is being cited under OSHA's Multi-Employer Workplace Policy.
Recent events (1)
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339352114.