Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: VEN-TEL PLASTICS CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of VEN-TEL PLASTICS CORPORATION in 11311 74TH ST. N, LARGO, FL 33773 (NAICS 326199). OSHA activity number 339359481.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ven-Tel Plastics Corporation for free Get an email when a new federal OSHA severe-injury report for Ven-Tel Plastics Corporation is published. One employer, no account, unsubscribe in one click.
Site address
11311 74TH ST. N
City
LARGO
State
FL
ZIP
33773
Mailing
11311 74TH ST. N, LARGO, FL 33773
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
80
Ownership type
Private (A)

6 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 19, 2013
Penalty
Initial $2,380 · Current $1,428 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:   a) For the Ven-Tel facility at 11311 74th Street North, Largo, FL 33773, as observed on or about 08/27/2013, employees were exposed to unguarded sections of unused blade on a horizontal metal bandsaw. On the left side of the saw, the unused blade was measured to be 8.5 inches long, and on the right side of the saw, the unused blade was measured to be 5.5 inches long. Employees operating the saw were exposed to potential laceration hazards due to the unguarded saw blade.
Recent events (2)
  • · I (S) $1428
  • · Z (S) $2380

1910.147 C04 II

Serious Gravity 5 3 instances 27 exposed
Issued
Sep 19, 2013
Abate by
Oct 23, 2013
Penalty
Initial $2,380 · Current $1,428 Reduced
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):   For the Ven-Tel facility at 11311 74th Street North, Largo, FL 33773, as observed on or about 08/27/2013, lockout tagout procedures were only general in nature and not specific to the machinery on which lockout tagout was performed, in that:   a) Specific steps on the application of locks or tags to machine specific energy isolating sources were not present.   b) Specific procedures for testing a machine or equipment to determine and verify effectiveness of lockout tagout devices and other energy control measures were not present.   c) Procedural steps for shutting down and isolating machinery and equipment did not all identify what the energy isolating sources were and where they were located.
Recent events (2)
  • · I (S) $1428
  • · Z (S) $2380

1910.147 C06 II

Serious Gravity 5 1 instance 27 exposed
Issued
Sep 19, 2013
Abate by
Oct 23, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(ii):  The periodic inspection certification of energy control procedures did not contain the required documentation as to identification of the machine or equipment, inspection date, employees included, and the person performing the inspection:   a) For the Ven-Tel facility at 11311 74th Street North, Largo, FL 33773, as observed on or about 08/27/2013, documentation for the certification of annual inspections for lockout tagout procedures was not available.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.215 A04

Serious Gravity 5 1 instance 10 exposed
Issued
Sep 19, 2013
Penalty
Initial $2,380 · Current $1,428 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:   For the Ven-Tel facility at 11311 74th Street North, Largo, FL 33773, as observed on or about 08/27/2013, tool rests on abrasive wheel bench grinders were not adjusted to have a gap between the tool rest and abrasive wheel of 1/8 inches (0.125-inches) or less:          a) In the maintenance shop, the gap between tool rest and abrasive wheel was 1.125 inches.       b) In the tool/die cleaning room, the gap between tool rest and abrasive wheel was 0.31 inches.
Recent events (2)
  • · I (S) $1428
  • · Z (S) $2380

1910.215 B09

Serious Gravity 5 2 instances 10 exposed
Issued
Sep 19, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9):  The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one-fourth inch (0.25):      For the Ven-Tel facility at 11311 74th Street North, Largo, FL 33773, as observed on or about 08/27/2013: tongue guards on multiple bench grinders were missing, and gaps between the abrasive wheel periphery and safety peripheral member were greater than ¼ inches:      a) In the maintenance shop, the gap between the abrasive wheel and safety peripheral member was 0.94 inches.   b) In the tool/die cleaning room, the gap between the abrasive wheel and safety peripheral member was 0.94 inches.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.305 G02 III

Other-than-serious 1 instance 1 exposed
Issued
Sep 19, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:      a) For the Ven-Tel facility at 11311 74th Street North, Largo, FL 33773, as observed on or about 08/27/2013, a power cord for a lathe had its outer insulation pulled away exposing inner wiring and placing strain on inner joints and terminal screws.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339359481.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.