Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GN ROOFING INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GN ROOFING INC. in 12008 IDA CIR, ENGLEWOOD, CO 80111 (NAICS 238160). OSHA activity number 339359531.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch GN Roofing INC. — free Get an email when a new federal OSHA severe-injury report for GN Roofing INC. is published. One employer, no account, unsubscribe in one click.
Establishment
GN ROOFING INC.
Site address
12008 IDA CIR
City
ENGLEWOOD
State
CO
ZIP
80111
Mailing
6403 E. LAGUNA CIR, HIGHLANDS RANCH, CO 80130
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

4 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 20, 2013
Abate by
Sep 30, 2013
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):   (a)  On or about August 27, 2013, the employer did not ensure that employees were protected from fall hazards of greater than 11 feet while removing roofing materials on a house without being tied off.     Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
  • — Z (S) $2800

1926.502 D17

Serious Gravity 10 1 instance 3 exposed
Issued
Sep 20, 2013
Abate by
Sep 30, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(17): The attachment point of the body harness was not located in the center of the wearer's back near shoulder level, or above the wearer's head:  (a)  On or about August 27, 2013, the employer did not ensure that employees were protected from injuries from a personal fall arrest system in which the employees tied off to a D-ring on the harness at the front of the body.  Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
  • — Z (S) $0

1926.503 A01

Serious Gravity 10 1 instance 4 exposed
Issued
Sep 20, 2013
Abate by
Sep 30, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:  (a)  On or about August 27, 2013, and at times prior, the employer did not instruct employees about fall hazards and the systems and procedures to follow to mitigate the hazards while removing old roofing material installing new material on a house.    Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
  • — Z (S) $0

1926.416 E01

Other-than-serious 1 instance 3 exposed
Issued
Sep 20, 2013
Abate by
Sep 30, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used:  (a)  On or about August 27, 2013, the employer did not ensure that employees were protected from electrical hazards from an extension cord used to power a circular saw that had cut insulation exposing the conductors inside.    Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
  • — Z (O) $0

View GN Roofing INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339359531.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.