Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PRESSED PAPERBOARD TECHNOLOGIES, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PRESSED PAPERBOARD TECHNOLOGIES, LLC in 115 BENTLY CT., FINDLAY, OH 45840 (NAICS 322299). OSHA activity number 339360505.

Watch Pressed Paperboard Technologies, LLC — free Get an email when a new federal OSHA severe-injury report for Pressed Paperboard Technologies, LLC is published. One employer, no account, unsubscribe in one click.
Site address
115 BENTLY CT.
City
FINDLAY
State
OH
ZIP
45840
Mailing
115 BENTLY CT, FINDLAY, OH 45840
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322299
Employees
110
Ownership type
A

8 citations on file for this inspection.

1910.137 B02 VIII

Serious Gravity 5 2 instances 14 exposed
Issued
Abate by
Penalty
Initial $4500.00 · Current $2250.00 Reduced
29 CFR 1910.137(b)(2)(viii): Electrical protective equipment was not subjected to periodic electrical tests in accordance with Tables I-5 and I-6:     A)    Pressed Paperboard Technologies, LLC, located at 115 Bentley Ct., Findlay, OH 45840: On or about August 12, 2013, the employer did not ensure that G.B. Industries electrical protective rubber gloves, used by maintenance employees during electrical troubleshooting and replacement of a fuse in the electrical panel 1P (Type LX 2353, Serial # PRPFP231217-06), were tested at least once every six months. Employees were exposed to 480 volts electrical hazards.      B)     Pressed Paperboard Technologies, LLC, located at 115 Bentley Ct., Findlay, OH 45840: On or about September 2, 2013, the employer did not ensure that Salisbury electrical protective rubber gloves, used by the maintenance employees during installation of the hand dryer's breaker in the electrical panel, were tested at least once every six months. Employees were exposed to 480 volts electrical hazards.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • — I (S) $2250
  • — Z (S) $4500

1910.147 C04 I

Serious Gravity 10 2 instances 24 exposed
Issued
Abate by
Penalty
Initial $6300.00 · Current $3150.00 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    A)    Pressed Paperboard Technologies, LLC, located at 115 Bentley Ct., Findlay, OH 45840: On or about August 26, 2013, the employer failed to develop machine-specific energy control procedures to control hazardous energy of Aquaflex Printing Press # 1 (Serial # PRPFP24943-99).  Employees did not isolate all energy sources in order to control hazards associated with rotating parts of the machine while performing activities such as, but not limited to, changing dies and cleaning Anilox rollers. Employees were exposed to amputation hazards.      B)     Pressed Paperboard Technologies, LLC, located at 115 Bentley Ct., Findlay, OH 45840: On or about August 26, 2013, the employer failed to develop machine-specific energy control procedures to control hazardous energy of the Bridgeport milling machine (Model F-7347-00-248, Serial # 1-18-0171) located in the facility's maintenance department.  Employees did not isolate the electrical energy source in order to control hazards associated with rotating parts of the machine while performing activities such as, but not limited to, changing drill bits. Employees were exposed to injury from unexpected start-up and energy release.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • — I (S) $3150
  • — Z (S) $6300

1910.147 C07 I

Serious Gravity 10 1 instance 24 exposed
Issued
Abate by
Penalty
Initial $6300.00 · Current $3150.00 Reduced
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program were understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls were acquired by employees:    A)    Pressed Paperboard Technologies, LLC, located at 115 Bentley Ct., Findlay, OH 45840: On or about August 26, 2013, the employer failed to properly train employees to lockout/tagout Aquaflex Printing Press # 1 (Serial # PRPFP24943-99) before employees conducted activities such as, but not limited to, changing dies and cleaning Anilox rollers. Employees were exposed to amputation hazards due to the lack of control of all hazardous energy sources prior to conducting work.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • — I (S) $3150
  • — Z (S) $6300

1910.212 A01

Serious Gravity 10 3 instances 38 exposed
Issued
Abate by
Penalty
Initial $6300.00 · Current $3150.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    A)    Pressed Paperboard Technologies, LLC, located at 115 Bentley Ct., Findlay, OH 45840: On or about August 26, 2013, the employer failed to ensure that one or more methods of machine guarding were provided to protect employees from nip point hazards that were created by the rotating rollers of Aquaflex Printing Press # 1 (Serial # PRPFP24943-99). Employees were at risk of injury when working in immediate proximity to the rotating rollers.      B)     Pressed Paperboard Technologies, LLC, located at 115 Bentley Ct., Findlay, OH 45840: On or about August 26, 2013, the employer failed to ensure that the Grizzly milling & drilling machine (Model G1006, Serial # 3519), located in the facility's maintenance department, was properly guarded in order to prevent employees from inadvertently being caught by the rotating chuck during the machine's operation.      C)     Pressed Paperboard Technologies, LLC, located at 115 Bentley Ct., Findlay, OH 45840: On or about August 12, 2013, the employer failed to ensure that the Bridgeport milling machine (Model F-7347-00-248, Serial # 1-18-0171), located in the facility's maintenance department, was properly guarded in order to prevent employees from inadvertently being caught by the rotating chuck during the machine's operation.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • — I (S) $3150
  • — Z (S) $6300

1910.333 A01

Serious Gravity 10 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $6300.00 · Current $3150.00 Reduced
29 CFR 1910.333(a)(1): Live parts to which an employee may be exposed were not deenergized before the employee worked on or was near to them:    A)    Pressed Paperboard Technologies, LLC, located at 115 Bentley Ct., Findlay, OH 45840: On or about August 12, 2013, 2013, the employer did not ensure that electrical panel 1P (Type LX 2353, Serial # PRPFP231217-06) was disconnected from all electric energy sources when maintenance employees replaced a fuse in the panel. The employee was exposed to 480 volt electrical hazards.      B)     Pressed Paperboard Technologies, LLC, located at 115 Bentley Ct., Findlay, OH 45840: On or about September 2, 2013, the employer did not ensure that the electrical panel, located in maintenance department, was disconnected from all electric energy sources when maintenance employees installed the hand dryer's breaker in the panel. The employee was exposed to 480 volt electrical hazards.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • — I (S) $3150
  • — Z (S) $6300

1910.332 B01

Willful Gravity 10 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $63000.00 · Current $31500.00 Reduced
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments:    A)    Pressed Paperboard Technologies, LLC, located at 115 Bentley Ct., Findlay, OH 45840: On or about August 12, 2013, the employer failed to ensure that maintenance employees were provided with training on electrical safety-related work practices such as, but not limited to, arc flash/blast hazards and protective equipment for the hands, head, and body to protect against electrical hazards while working on or near energized or potentially energized electrical parts. Employees were exposed to 480 volt electrical hazards while conducting electrical troubleshooting and replacing fuses in the energized electrical panel 1P (Type LX 2353, Serial # PRPFP231217-06) without locking the panel out and without proper electrical personal protective equipment.      B)     Pressed Paperboard Technologies, LLC, located at 115 Bentley Ct., Findlay, OH 45840: On or about September 2, 2013, the employer failed to ensure that maintenance employees were provided with training on electrical safety-related work practices such as, but not limited to, arc flash/blast hazards and protective equipment for the hands, head, and body to protect against electrical hazards while working on or near energized or potentially energized electrical parts. Employees were exposed to 480 volt electrical hazards while installing the hand dryer's breaker in the energized electrical panel without locking the panel out and without proper electrical personal protective equipment.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • — I (W) $31500
  • — Z (W) $63000

1910.333 C02

Willful Gravity 10 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.333(c)(2): The employer did not ensure that only qualified persons were working on energized circuits and that qualified persons were familiar with the proper use of special precautionary techniques, personal protective equipment, insulating and shielding materials, and insulated tools:  A)    Pressed Paperboard Technologies, LLC, located at 115 Bentley Ct., Findlay, OH 45840: On or about August 12, 2013, the employer failed to ensure that maintenance employees, who conducted electrical troubleshooting and replaced a fuse in the energized electrical panel 1P (Type LX 2353, Serial # PRPFP231217-06), were qualified to work on electric circuit parts or equipment that have not been deenergized. Employees were exposed to 480 volt electrical hazards.    B)     Pressed Paperboard Technologies, LLC, located at 115 Bentley Ct., Findlay, OH 45840: On or about September 2, 2013, the employer failed to ensure that maintenance employees, who installed the hand dryer's breaker in the energized electrical panel, were qualified to work on electric circuit parts or equipment that have not been deenergized. Employees were exposed to 480 volt electrical hazards.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • — I (W) $0
  • — Z (W) $0

1910.335 A01 I

Willful Gravity 10 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $63000.00 · Current $31500.00 Reduced
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed:    A)    Pressed Paperboard Technologies, LLC, located at 115 Bentley Ct., Findlay, OH 45840: On or about August 12, 2013, the employer did not ensure that maintenance employees, who conducted electrical troubleshooting and replaced a fuse in the energized electrical panel 1P (Type LX 2353, Serial # PRPFP231217-06), were provided with electrical personal protective equipment for the hands, head, and body. Employees were exposed to 480 volt electrical hazards.      B)     Pressed Paperboard Technologies, LLC, located at 115 Bentley Ct., Findlay, OH 45840: On or about September 2, 2013, the employer did not ensure that maintenance employees, who installed the hand dryer's breaker in the energized electrical panel, were provided with electrical personal protective equipment for the hands, head, and body. Employees were exposed to 480 volt electrical hazards.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • — I (W) $31500
  • — Z (W) $63000

View PRESSED PAPERBOARD TECHNOLOGIES, LLC's full OSHA safety record →