SAN ANTONIO, TX —
OSHA Inspection: FRANKS MANUFACTURING COMPANY, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of FRANKS MANUFACTURING COMPANY, INC. in 1336 W. BLANCO, SAN ANTONIO, TX 78232 (NAICS 326199). OSHA activity number 339362543.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FRANKS MANUFACTURING COMPANY, INC.
- Site address
- 1336 W. BLANCO
- City
- SAN ANTONIO
- State
- TX
- ZIP
- 78232
- Mailing
- 1336 W. BLANCO, SAN ANTONIO, TX 78232
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 13
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.22 D01
- Issued
- Dec 13, 2013
- Abate by
- Dec 28, 2013
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate: (a) Building #1, Northeast side: On or about August 28, 2013, employees were exposed to a struck-by hazard from materials that were stored above an area used as office space that was not rated for a load capacity or for storage use. (b) Building #1, Southeast side: On or about August 28, 2013, employees were exposed to a struck-by hazard from materials that were stored above an area used as office space, the employee time clock area and supply area that was not rated for a load capacity or for storage use. (c) Building #2, South side: On or about August 28, 2013, employees were exposed to a struck-by hazard from materials that were stored above an area near the CNC room and welding areas that was accessed by employees and was not rated for a load capacity or for storage use.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1910.212 B
- Issued
- Dec 13, 2013
- Abate by
- Dec 28, 2013
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: (a) Building #1, South side: On or about August 28, 2013, employee(s) were exposed to struck-by and caught-in hazards from a JET drill press (Model: JDP-17MF) which was anchored to a damaged wooden palette and was moved around the warehouse by employees for fabrication process use. (b) Building #1, South side: On or about August 28, 2013, employee(s) were exposed to struck-by and caught-in hazards from a JET drill press (Model: JDP-17MF) which was anchored to a wheeled wooden platform and was moved around the warehouse by employees for fabrication process use. (c) Building #1, North side: On or about August 28, 2013, employee(s) were exposed to struck-by and caught-in hazards from a two JET bandsaws which were anchored to wheeled wooden platforms and were moved around the warehouse by employees for fabrication process use. (d) Building #1, North side: On or about August 28, 2013, employee(s) were exposed to struck-by and caught-in hazards from a Rikon bandsaw (Model: 10-325) which was anchored to a wheeled wooden platform and was moved around the warehouse by employees for fabrication process use.
Recent events (2)
- — I (S) $960
- — Z (S) $1600
1910.253 B04 I
- Issued
- Dec 13, 2013
- Abate by
- Dec 28, 2013
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire: Building #2, South side: On or about August 28, 2013, employees were exposed to a fire hazard from full oxygen and acetylene compressed gas cylinders which were stored together in the building's compressed gas cylinder storage area.
Recent events (2)
- — I (S) $960
- — Z (S) $1600
1910.305 B01 II
- Issued
- Dec 13, 2013
- Abate by
- Dec 28, 2013
- Penalty
- Initial $2,400 · Current $1,440 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: (a) Building #1, West side: On or about August 28, 2013, employee(s) were exposed to an electrical hazard from an electrical panel box which was used to control power to the facility and was lacking blank panels to effectively close the box. (b) Building #2, Southeast side: On or about August 28, 2013, employee(s) were exposed to an electrical hazard from an electrical control box which was used to power a vacuum forming machine for plastic fabrication processes and was lacking panels to effectively close the box. (c) Building #2, East side: On or about August 28, 2013, employee(s) were exposed to an electrical hazard from an electrical panel box which was lacking blank panels to effectively close the box.
Recent events (2)
- — I (S) $1440
- — Z (S) $2400
1910.334 A01
- Issued
- Dec 13, 2013
- Abate by
- Dec 28, 2013
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1910.334(a)(1): Flexible electric cords were fastened with staples or otherwise hung in such a fashion as could damage the outer jacket or insulation: Building #1, West side: On or about August 28, 2013 employees were exposed to an electrical hazard from a flexible electrical cord which was used to power a Porter Cable Router (Model 6912) and was hung over a metal beam in a fashion that could damage the outer jacket of the cord.
Recent events (2)
- — I (S) $960
- — Z (S) $1600
1910.334 A02 II
- Issued
- Dec 13, 2013
- Abate by
- Dec 28, 2013
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service and an employee was using it before repairs and tests necessary to render the equipment safe were made: Building #1, West side: On or about August 28, 2013, employee(s) were exposed to an electrical hazard from the use of a Porter Cable Router (Model 6912) with a frayed and damaged electrical cord which had exposed wiring and electrical tape.
Recent events (2)
- — I (S) $960
- — Z (S) $1600
More inspections at Franks Manufacturing Company, INC.
View Franks Manufacturing Company, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339362543.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.