HAZLETON, PA —
OSHA Inspection: SIMONA AMERICA INCORPORATED
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SIMONA AMERICA INCORPORATED in 64 N. CONAHAN DR, HAZLETON, PA 18201 (NAICS 326113). OSHA activity number 339363483.
Where did this inspection happen?
- Establishment
- SIMONA AMERICA INCORPORATED
- Site address
- 64 N. CONAHAN DR
- City
- HAZLETON
- State
- PA
- ZIP
- 18201
- Mailing
- 64 N. CONAHAN DR, HAZLETON, PA 18201
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326113
- Employees
- 70
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $2380.00 · Current $1500.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: Production area: The Breyer haul off rollers on extrusion lines #4 and 5 were not properly guarded. An employee sustained a severe injury when his hand became trapped between the first set of haul off rollers on Line #5, on or about August 19, 2013. Abatement Certification Required.
Recent events (2)
- — I (S) $1500
- — Z (S) $2380
1910.216 C02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.216(c)(2): A cable or wire center cord, connected to the safety trip, was not provided on both sides of the calender and near each end of the face of the rolls: Production area: Emergency safety cables or wires were not provided on the sides of Line #4 and 5 calender rollers, as observed on or about August 29, 2013. Abatement Certification Required.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 F02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using a tight-fitting facepiece respirator were not annually fit tested: a) Mixing room: An employee using a tight fitting half face air purifying respirator was not annually fit tested, on or about August 29, 2013. Abatement Certification Required.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at SIMONA AMERICA INCORPORATED
HAZLETON, PA—2009-04-09 00:00:00
SIMONA AMERICA INCORPORATED
View SIMONA AMERICA INCORPORATED's full OSHA safety record →
More inspections in this industry (NAICS 326113)
NARRAGANSETT, RI—2026-07-09
ROGERS CORPORATION
RURAL RETREAT, VA—2026-07-07
KLOCKNER PENTAPLAST OF AMERICA, INC.
SUTTON, MA—2026-07-01
POLYVINYL FILMS, INC.
GARFIELD, NJ—2026-05-22
PRIMEX PLASTICS CORPORATION
FERNLEY, NV—2026-05-21
AGRU AMERICA, INC.
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source