SCHUYLER, NE ·
OSHA Inspection: NORAM LOGISTICS, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NORAM LOGISTICS, LLC in 481 ROAD 9, SCHUYLER, NE 68661 (NAICS 493120). OSHA activity number 339367104.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NORAM LOGISTICS, LLC
- Site address
- 481 ROAD 9
- City
- SCHUYLER
- State
- NE
- ZIP
- 68661
- Mailing
- 481 ROAD 9, SCHUYLER, NE 68661
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493120
- Employees
- 39
- Ownership type
- Private (A)
Citations
8 citations on file for this inspection.
1910.119 D03 I H
- Issued
- Sep 30, 2013
- Abate by
- Nov 22, 2014
- Penalty
- Initial $4,500 · Current $2,250 Reduced
General-duty citation text
29 CFR 1910.119(d)(3)(i)(H): The employer has failed to ensure that Process Safety Information pertaining to the Safety Systems was collected, maintained, and documented as part of the Process Safety Management Program. Work site located at 481 Road 9, Schuyler, NE; Throughout the Company: The employer has failed to maintain documentation (Process Safety Information) and document Safety Devices for an anhydrous ammonia refrigeration system comply with recognized and generally accepted good engineering practices. Abatement certification is required for this violation. The abatement certification sheet is enclosed for the citations.
Recent events (3)
- · F (O) $2250
- · C (S) $4500
- · Z (S) $4500
1910.119 F01 III B
- Issued
- Sep 30, 2013
- Abate by
- Nov 22, 2014
- Penalty
- Initial $4,500 · Current $2,250 Reduced
General-duty citation text
29 CFR 1910.119(f)(1)(iii)(B): The employer has failed to develop and implement an operating procedure discussing the precautions necessary to prevent exposure; including engineering controls, administrative controls, and personal protective equipment. Work site located at 481 Road 9, Schuyler, NE; Throughout the Company: The employer did not develop an operating procedure that that addresses how the employees will be protected from exposure to anhydrous ammonia. The company has developed basic procedures that discuss the production process but nothing that indicates how the employees are protected or how they would be protected in the event of an upset condition i.e. engineering control, PPE, or some other method. Abatement certification is required for this violation. The abatement certification sheet is enclosed with the citations.
Recent events (3)
- · F (O) $2250
- · C (S) $4500
- · Z (S) $4500
1910.119 F01 III C
- Issued
- Sep 30, 2013
- Abate by
- Nov 22, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(f)(1)(iii)(C): The employer has failed to develop and implement an operating procedure discussing the control measures to be taken if physical contact or airborne exposure occurs. Work site located at 481 Road 9, Schuyler, NE; Throughout the Company: The employer did not develop an operating procedure that discusses what actions will be taken in the event of an exposure to anhydrous ammonia. The employer has failed to develop a procedure for response actions for employee exposure that would include but is not limited to event escalation, emergency response, or containment. Abatement certification is required for this violation. The abatement certification sheet is enclosed with the citations.
Recent events (3)
- · F (O) $0
- · C (S) $0
- · Z (S) $0
1910.119 J02
- Issued
- Sep 30, 2013
- Abate by
- Nov 1, 2013
- Penalty
- Initial $4,500 · Current $0 Reduced
General-duty citation text
29 CFR 1910.119(j)(2): The employer didnt establish and implement written procedures to maintain the on-going integrity of process equipment. Worksite located at 481 Road 9, Schuyler, NE; Throughout the Facility: The employer has not developed any procedures for ensuring the mechanical integrity of the system. This would include a program outlining preventative maintenance, component replacement, and/or repair. One such example would be a valve replacement procedure to include a change out schedule for safety relieve valves. Abatement certification is required for this violation. The abatement certification sheet is enclosed for the citations.
Recent events (3)
- · F (S) $0
- · C (S) $4500
- · Z (S) $4500
1910.119 J05
- Issued
- Sep 30, 2013
- Abate by
- Nov 1, 2013
- Penalty
- Initial $4,500 · Current $0 Reduced
General-duty citation text
29 CFR 1910.119(j)(5): The employer failed to correct deficiencies in equipment that is outside acceptable limits (defined by the process safety information in paragraph (d) of this section) before further use or in a safe and timely manner when necessary means are taken to assure safe operation. Work site located at 481 Road 9, Schuyler, NE; Engine Room: Rusted piping and minor damage to insulation had not been addressed. The rust on process piping is considered outside of acceptable limits and must be remediated. Abatement certification is required for this violation. The abatement certification sheet is enclosed for the citations.
Recent events (3)
- · F (S) $0
- · C (S) $4500
- · Z (S) $4500
1910.119 N
- Issued
- Sep 30, 2013
- Abate by
- Nov 22, 2014
- Penalty
- Initial $6,300 · Current $3,150 Reduced
General-duty citation text
29 CFR 1910.119(n): The employer did not establish an emergency plan for the entire plant in accordance with the provisions of 29 CFR 1910.38:(a) Work site located at 481 Road 9, Schuyler, NE; throughout the company.: The employer has not developed exit routes for the employees to follow in the event of an evacuation and then provide training regarding those routes. The facility is not equipped with an alarm system which will notify employees of an evacuation order which can be heard in all areas of the facility. Areas of the facility do not have notification systems. The facility uses ammonia as part of their refrigeration system and a release could harm any employee that does not evacuate to a safe, predetermined area. The evacuation plan should include a method for determining the safe route and rally point utilizing a wind sock to determine the safe upwind predetermined evacuation location. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citations.
Recent events (3)
- · F (S) $3150
- · C (S) $6300
- · Z (S) $6300
1910.147 C04 I
- Issued
- Sep 30, 2013
- Abate by
- Nov 22, 2014
- Penalty
- Initial $4,500 · Current $2,250 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: Worksite located at 481 Road 9, Schuyler, NE; Throughout the facility: Procedures were not developed to protect employees from unexpected energization, start up, or release of stored energy. This includes but is not limited to conveyors and a compactor. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of the abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citations.
Recent events (3)
- · F (S) $2250
- · C (S) $4500
- · Z (S) $4500
1910.176 B
- Issued
- Sep 30, 2013
- Abate by
- Nov 1, 2013
- Penalty
- Initial $3,600 · Current $0 Reduced
General-duty citation text
29 CFR 1910.176(b): Storage of Material created a hazard (based on improper installation and use). Worksite located at 481 Road 9, Schuyler, NE; Receiving Area: The storage racks within the cold storage warehouses have sustained damage that could compromise the strength and stability of the system. Abatement certification is required for this violation. The abatement certification sheet is enclosed for the citations.
Recent events (3)
- · F (S) $0
- · C (S) $3600
- · Z (S) $3600
More inspections at Noram Logistics, LLC
View Noram Logistics, LLC's full OSHA safety record →
More inspections in this industry (NAICS 493120)
More inspections in NE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339367104.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.