Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CENTENNIAL MOISTURE CONTROL, INC.

Federal Agency inspection · Health discipline

On , OSHA opened a federal Agency health inspection of CENTENNIAL MOISTURE CONTROL, INC. in 3032 BRINKLEY AVENUE, DALLAS, TX 75205 (NAICS 238990). OSHA activity number 339368045.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Centennial Moisture Control, INC. — free Get an email when a new federal OSHA severe-injury report for Centennial Moisture Control, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3032 BRINKLEY AVENUE
City
DALLAS
State
TX
ZIP
75205
Mailing
1780 HURD DRIVE, IRVING, TX 75038
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
49
Ownership type
A

5 citations on file for this inspection.

1910.134 C01

Serious Gravity 10 3 instances 2 exposed
Issued
Feb 21, 2014
Abate by
Mar 5, 2014
Penalty
Initial $5,390 · Current $7,000
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:      The employer does not establish and implement a written respiratory protection program with worksite specific procedures. This violation occurred on August 31, 2013 and at times prior thereto, at a jobsite located at 3009 Binkley Avenue, Dallas, Texas; where the employer did not establish and implement a written respiratory protection program with worksite specific procedures for employees wearing supplied-air respirators:    Instance a: Procedures to ensure adequate air quality for atmosphere supplying respirators;      Instance b: Training of employees in the respiratory hazards to which they are potentially exposed during routine and emergency situations;      Instance c: Procedures for regularly evaluating the effectiveness of the program.
Recent events (3)
  • — F (S) $7000
  • — C (S) $5390
  • — Z (S) $5390

1910.134 C03

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 21, 2014
Abate by
Mar 5, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(3): The employer did not designate a program administrator who was qualified by appropriate training or experience to administer or oversee the respiratory protection program and to conduct the required evaluations of program effectiveness:    The employer does not designate a qualified program administrator. This violation occurred on August 31, 2013 and at times prior thereto, at a jobsite located at 3009 Binkley Avenue, Dallas, Texas; where the employer did not designate a qualified program administrator to administer or oversee the respiratory protection program and to conduct the required evaluations of program effectiveness.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.134 I01 II

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 21, 2014
Abate by
Mar 5, 2014
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.134(i)(1)(ii): Breathing air did not meet requirements for Grade D breathing air as described in the ANSI/Compressed Gas Association Commodity Specification G-7.1-1989:    The employer does not ensure compressed breathing air meets at least the requirements for Grade D breathing air. This violation occurred on August 31, 2013 and at times prior thereto, at a jobsite located at 3009 Binkley Avenue, Dallas, Texas; where the employer did not ensure that breathing air provided to employees wearing a Nova 2000 abrasive blasting helmet met at least the requirements for Grade D breathing air.
Recent events (3)
  • — F (S) $0
  • — C (S) $7000
  • — Z (S) $7000

1910.134 I07

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 21, 2014
Abate by
Mar 5, 2014
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.134(i)(7): For oil-lubricated compressors, the employer did not use a high-temperature or carbon monoxide alarm, or both, to monitor carbon monoxide levels:    The employer does not monitor for carbon monoxide levels. This violation occurred on August 31, 2013 and at times prior thereto, at a workplace located at 3009 Binkley Avenue, Dallas, Texas; where the employer did not use an alarm and exposed employees wearing a Nova 2000 abrasive blasting to carbon monoxide.
Recent events (3)
  • — F (S) $0
  • — C (S) $7000
  • — Z (S) $7000

1910.134 I05 I

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Feb 21, 2014
Abate by
Mar 5, 2014
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.134(i)(5)(i): Compressors used to supply breathing air to respirators were not so constructed and situated so as to prevent entry of contaminated air into the air-supply system:   The employer does not situate compressors as to prevent entry of contaminated air into the air-supply system. This violation occurred on August 31, 2013 and at times prior thereto, at a jobsite located at 3009 Binkley Avenue, Dallas, Texas; where an Ingersoll-Rand air compressor used to supply breathing air to employees wearing a Nova 2000 abrasive blasting helmet was located inside the coliseum in close proximity to the crash wall.
Recent events (3)
  • — F (S) $0
  • — C (S) $7000
  • — Z (S) $7000

View Centennial Moisture Control, INC.'s full OSHA safety record →