OSHA Inspection: EAKINS PRESS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of EAKINS PRESS, INC. in 1111 KENNETH, NIXA, MO 65714 (NAICS 323111). OSHA activity number 339371833.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Eakins Press, INC. — free Get an email when a new federal OSHA severe-injury report for Eakins Press, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
EAKINS PRESS, INC.
Site address
1111 KENNETH
City
NIXA
State
MO
ZIP
65714
Mailing
P.O. BOX 518, NIXA, MO 65714
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323111
Employees
16
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 II B

Serious Gravity 5 2 instances 1 exposed
Issued
Sep 26, 2013
Abate by
Jan 21, 2014
Penalty
Initial $1,600 · Current $640 Reduced
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy:    (a)  Press Room:  Employees were exposed to electrical hazards as equipment, such as, but not limited to, the Mitsubishi Four Color Press, and the Mueller stitcher, do not have machine specific procedures for lockout tagout explaining where to lockout and tagout each piece of equipment that is hardwired in, has more than one power source, or is not locked out at the machine.      Abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.    NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM.  FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19
Recent events (3)
  • — F (S) $640
  • — C (S) $1600
  • — Z (S) $1600

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 26, 2013
Abate by
Jan 21, 2014
Penalty
Initial $1,600 · Current $640 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    (a) Bindery Pressroom:  Employees were exposed to rotating parts as the Saddlestitch Binder had the plexiglass guard broken on the east end of the machine.    Abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.    NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM.  FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19
Recent events (3)
  • — F (S) $640
  • — C (S) $1600
  • — Z (S) $1600

1910.303 B02

Serious Gravity 5 2 instances 6 exposed
Issued
Sep 26, 2013
Abate by
Jan 21, 2014
Penalty
Initial $1,600 · Current $640 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    (a) Prepress:  Employees were exposed to electrical hazards as a metal pendant four-plex electrical box with prepunched knockouts was not being used per listing as labeling instructions.  Metal boxes with prepunched knockouts are listed or labeled to be mounted to a wall or a piece of equipment.    (b) Dock Door Area: Employees were exposed to electrical hazards as a metal box with prepunched knockouts was being used as an extension cord to charge the forklift battery.  Metal boxes with prepunched knockouts are listed or labeled to be mounted to a wall or a piece of equipment.    Abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.    NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM.  FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19
Recent events (3)
  • — F (S) $640
  • — C (S) $1600
  • — Z (S) $1600

1910.305 G01 IV

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 26, 2013
Abate by
Jan 21, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv):    (a) Prepress:  Employees were exposed to electrical hazards as the electrical cord being used as a cord for the metal pendant box with prepunched knockouts was subject to abrasion as the cord was run through the ceiling. Flexible cord can not be run through holes in ceilings.    Abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.    NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM.  FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0