Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-02

OSHA Inspection: RICHMOND AMERICAN HOMES OF COLORADO, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RICHMOND AMERICAN HOMES OF COLORADO, INC. in 25603 E. CALHOUN PLACE, AURORA, CO 80016 (NAICS 236115). OSHA activity number 339373235.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Richmond American Homes of Colorado, INC. for free Get an email when a new federal OSHA severe-injury report for Richmond American Homes of Colorado, INC. is published. One employer, no account, unsubscribe in one click.
Site address
25603 E. CALHOUN PLACE
City
AURORA
State
CO
ZIP
80016
Mailing
4350 S. MONACO STREET, DENVER, CO 80237
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
4
Ownership type
A

4 citations on file for this inspection.

1926.451 A06

Other-than-serious 6 instances 4 exposed
Issued
Sep 24, 2013
Abate by
Sep 30, 2013
Penalty
Initial $3,825 · Current $7,000
29 CFR 1926.451(a)(6): Scaffolds were not constructed in accordance with the design by a qualified person:    a)  On or about September 3, 2013, and at times prior, Richmond American Homes of Colorado, Inc., as a controlling employer, did not ensure that P and A Concrete and Construction, Ltd. (subcontractor) protected their employees from falls while they worked on fabricated frame scaffold which had not been constructed per the design nor by a qualified person.  Several platforms were constructed of planks that rested on 2x4s that were tied to the frame with wire.  These planks should have rested on the bearer section of the frame as it was designed.
Recent events (2)
  • · I (O) $7000
  • · Z (S) $3825

1926.451 B01

Other-than-serious 6 instances 4 exposed
Issued
Sep 24, 2013
Abate by
Sep 30, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.451(b)(1):  Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii):      a)  On or about September 3, 2013, and at times prior, Richmond American Homes of Colorado, Inc., as a controlling employer, did not ensure that P and A Concrete and Construction, Ltd. (subcontractor) protected their employees from falls while they worked on fabricated frame scaffold which had not been fully planked.  Scaffold levels at 13 feet and above were equipped with only two of the three planks for which they were designed.
Recent events (2)
  • · I (O) $0
  • · Z (S) $0

1926.451 G01

Other-than-serious 5 instances 4 exposed
Issued
Sep 24, 2013
Abate by
Sep 30, 2013
Penalty
Initial $3,825 · Current $0 Reduced
29 CFR 1926.451(g)(1):  Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:    a)  On or about September 3, 2013, and at times prior, Richmond American Homes of Colorado, Inc., as a controlling employer, did not ensure that P and A Concrete and Construction, Ltd. (subcontractor) protected their employees from falls while they worked on fabricated frame scaffold which did not have standard guardrails on platforms that were 13 feet and higher.  No other fall protection measures were in place.
Recent events (2)
  • · I (O) $0
  • · Z (S) $3825

1926.451 E01

Deleted Serious Gravity 5 2 instances 4 exposed
Issued
Sep 24, 2013
Abate by
Sep 30, 2013
Penalty
Initial $3,825 · Current $0 Reduced
29 CFR 1926.451(e)(1):  When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surfaces were not used as a means of access:  a)  On or about September 3, 2013, and at times prior, Richmond American Homes of Colorado, Inc., as a controlling employer, did not ensure that P and A Concrete and Construction, Ltd. (subcontractor) protected their employees from falls  by providing a ladder to access upper levels of scaffolding from the ground and the roof of a single family home.  Employees climbed the frame of the scaffold itself.
Recent events (2)
  • · I (S) $0
  • · Z (S) $3825

View Richmond American Homes of Colorado, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339373235.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.