POMPANO BEACH, FL ·
OSHA Inspection: FLORIDA'S ULTIMATE HEAVY HAULING, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of FLORIDA'S ULTIMATE HEAVY HAULING, LLC in 1750 N POWERLINE ROAD, POMPANO BEACH, FL 33069 (NAICS 484220). OSHA activity number 339374696.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FLORIDA'S ULTIMATE HEAVY HAULING, LLC
- Site address
- 1750 N POWERLINE ROAD
- City
- POMPANO BEACH
- State
- FL
- ZIP
- 33069
- Mailing
- 1750 N POWERLINE ROAD, POMPANO BEACH, FL 33069
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 484220
- Employees
- 11
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.180 D03
- Issued
- Feb 11, 2014
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1910.180(d)(3)(iii): Frequent Inspections were not conducted to identify whether safety devices were fully functioning. a. On or about August 30, 2013, at the above addressed jobsite, three employees were operating a rough-terrain/self-propelled crane, which was not inspected daily, and/or monthly, and for which was known by the operator to have an inoperative "operational aid" (anti two-blocking device), and for which a "temporary alternative measure" had not been implemented, which resulted in the auxiliary hoist rope failure.
Recent events (1)
- · Z (S) $2800
1910.180 D04
- Issued
- Feb 11, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.180(d)(4): Complete inspection(s) of crane(s) were not performed at intervals as generally defined in 1910.180(d)(ii) with a determination made as to whether deficiencies constituted a safety hazard: a. On or about August 30, 2013, at the above addressed jobsite, three employees were operating a rough-terrain/self-propelled crane, which was not inspected annually, and for which was known by the operator to have an inoperative load indicator, boom angle indicator, or other inoperative indicator (anti two-blocking device); subpart(d)(4)(vi), and for which a "temporary alternative measure" had not been implemented, which resulted in the auxiliary hoist rope failure.
Recent events (1)
- · Z (S) $0
More inspections in this industry (NAICS 484220)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339374696.