Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LUCIFER LIGHTING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LUCIFER LIGHTING in 3750 N IH 35, SAN ANTONIO, TX 78219 (NAICS 335121). OSHA activity number 339390890.

Watch Lucifer Lighting — free Get an email when a new federal OSHA severe-injury report for Lucifer Lighting is published. One employer, no account, unsubscribe in one click.
Establishment
LUCIFER LIGHTING
Site address
3750 N IH 35
City
SAN ANTONIO
State
TX
ZIP
78219
Mailing
3750 N IH 35, SAN ANTONIO, TX 78219
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335121
Employees
85
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 5 2 instances 5 exposed
Issued
Dec 26, 2013
Abate by
Jan 30, 2014
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.147(c)(4)(ii): The procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C), and (c)(4)(ii)(D):   a)  Machine Shop, east wall, Acurpress hydraulic press brake, Model No. 7606, Serial No. 10139:   On or about September 4, 2013, employees were exposed to the release of hazardous energy, in that the written energy control procedures did not specifically identify all energy sources, such as gravitational, hydraulic and electrical energy, for employees engaged in the performance of servicing and/or maintenance activities.   b)  Machine Shop, east wall, Acurpress hydraulic press brake, Model No. 7608, Serial No. 11192:   On or about September 4, 2013, employees were exposed to the release of hazardous energy, in that the written energy control procedures did not specifically identlfy all energy sources, such as gravitational, hydraulic and electrical energy, for employees engaged in the performance of servicing and/or maintenance activities.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.147 C07 I

Serious Gravity 5 2 instances 5 exposed
Issued
Dec 26, 2013
Abate by
Jan 30, 2014
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees:   a) Machine Shop, east wall, Acurpress hydraulic press brake, Model No. 7606, Serial No. 10139:  On or about September 4, 2013, employees were exposed to hazardous energy including but not limited to electrical at 460 volts, as well as gravitational energy, while conducting maintenance activities.   b) Machine Shop, east wall, Acurpress hydraulic press brake, Model No. 7608, Serial No. 11192:  On or about September 4, 2013, employees were exposed to hazardous energy including but not limited to electrical at 460 volts, as well as gravitational energy, while conducting maintenance activities.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.212 A03 II

Serious Gravity 5 3 instances 5 exposed
Issued
Dec 26, 2013
Abate by
Jan 30, 2014
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.212(a)(3)(ii):  The point of operation of machines whose operation exposes an employee to injury, was not guarded to prevent the operator from having any part of his body in the danger zone during the operating cycle:   a)  Machine shop, east wall, Accurpress hydraulic 60-ton press brake, Model No. 7608, Serial No. 11192:  On or about September 4, 2013, employee(s) were exposed to an amputation hazard while operating the press brake, as the employees' hands are approximately 2 inches from the unguarded point of operation.  b)  Machine Shop, east wall, Accurpress hydraulic 60-ton press brake, Model No. 7606, Serial No. 10139:  On or about September 4, 2013, employees were exposed to a caught-in hazard at the unguarded rear area of the 6-foot  press brake, while they stored and retrieved tools.  c)  Machine Shop, east wall, Accurpress hydraulic 60-ton press brake, Model No. 7608, Serial No. 11192:  On or about September 4, 2013, employees were exposed to a caught-in hazard at the unguarded rear area of the 8-foot press brake, while they stored and retrieved tools.