ALLENTOWN, PA ·
OSHA Inspection: BOULEVARD FRAME & ART
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BOULEVARD FRAME & ART in 1009 UNION BOULEVARD, ALLENTOWN, PA 18109 (NAICS 442299). OSHA activity number 339391138.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BOULEVARD FRAME & ART
- Site address
- 1009 UNION BOULEVARD
- City
- ALLENTOWN
- State
- PA
- ZIP
- 18109
- Mailing
- 1009 UNION BOULEVARD, ALLENTOWN, PA 18109
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 442299
- Employees
- 3
- Ownership type
- A
Citations
3 citations on file for this inspection.
5(a)(1)
- Issued
- Sep 27, 2013
- Abate by
- Nov 1, 2013
- Penalty
- Initial $1,600 · Current $1,120 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to laceration hazards due to improperly designed and maintained machine tool foot treadles: a) Rear Room - The foot pedal on the Sampson Metal Cutter Machine was not guarded and had a damaged air control valve which prevented proper system cycling and did not preclude inadvertent operation, on or about 8/27/13. Among other methods, one feasible means of abatement would be to guard and repair the foot pedal to proper working order in accordance with paragraph 4.2.3.2 of ANSI B11.10, "Safety Requirements for Construction, Care, and Use of Metal Sawing Machines".
Recent events (2)
- · I (S) $1120
- · Z (S) $1600
1910.36 G02
- Issued
- Sep 27, 2013
- Abate by
- Oct 7, 2013
- Penalty
- Initial $1,200 · Current $840 Reduced
General-duty citation text
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points. a) Back Room - a wood cutting saw extended into a door frame opening, restricting the exit access to a width of 23 inches, on or about 8/27/13.
Recent events (2)
- · I (S) $840
- · Z (S) $1200
1910.147 C01
- Issued
- Sep 27, 2013
- Abate by
- Nov 1, 2013
- Penalty
- Initial $1,600 · Current $1,120 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) Throughout Facility - an hazardous energy control program was not developed for employee use while conducting maintenance on production equipment, including metal and wood cutting saws, on or about 8/27/13.
Recent events (2)
- · I (S) $1120
- · Z (S) $1600
More inspections in this industry (NAICS 442299)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339391138.