GRANITE CITY, IL —
OSHA Inspection: MAYCO INDUSTRIES, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MAYCO INDUSTRIES, INC. in 1200 16TH STREET, GRANITE CITY, IL 62040 (NAICS 331419). OSHA activity number 339395717.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MAYCO INDUSTRIES, INC.
- Site address
- 1200 16TH STREET
- City
- GRANITE CITY
- State
- IL
- ZIP
- 62040
- Mailing
- 1200 16TH STREET, GRANITE CITY, IL 62040
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331419
- Employees
- 21
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.253 E05 V
- Issued
- Jan 27, 2014
- Abate by
- Jan 31, 2014
- Penalty
- Initial $2,800 · Current $1,950 Reduced
General-duty citation text
29 CFR 1910.253(e)(5)(v): Hose showing leaks, burns, worn places, or other defects rendering it unfit for service were not repaired or replaced: Employees are exposed to burns while operating a oxygen and fuel torch which contained defects on the hoses such as bubbling, and kinks.
Recent events (2)
- — I (S) $1950
- — Z (S) $2800
1910.303 B02
- Issued
- Jan 27, 2014
- Abate by
- Jan 31, 2014
- Penalty
- Initial $2,800 · Current $1,950 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: Employees are exposed to electrical shock due to metal electrical boxes were used as parts to extension cords, and the boxes were not used in accordance with listing or labeling requirements.
Recent events (2)
- — I (S) $1950
- — Z (S) $2800
1910.22 D01
- Issued
- Jan 27, 2014
- Abate by
- Feb 21, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate. The lofts in the warehouse were not marked to show the loads approved by a building official.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Mayco Industries, INC.