Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: C & C MARINE AND REPAIR, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of C & C MARINE AND REPAIR, LLC in 701 ENGINEERS RD., BELLE CHASSE, LA 70037 (NAICS 336611). OSHA activity number 339396079.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch C & C Marine and Repair, LLC — free Get an email when a new federal OSHA severe-injury report for C & C Marine and Repair, LLC is published. One employer, no account, unsubscribe in one click.
Site address
701 ENGINEERS RD.
City
BELLE CHASSE
State
LA
ZIP
70037
Mailing
701 ENGINEERS RD., BELLE CHASSE, LA 70037
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336611
Employees
80
Ownership type
A

11 citations on file for this inspection.

1910.178 L01 I

Serious Gravity 5 10 instances 20 exposed
Issued
Oct 17, 2013
Abate by
Dec 5, 2013
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):   a) Throughout the facility; On or about 9/5/13, the employer failed to train forklift operators on the operation of Toyota forklifts and other forklift types used in the facility.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3500

1910.180 D03 III

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 17, 2013
Abate by
Oct 31, 2013
Penalty
Initial $3,500 · Current $1,050 Reduced
29 CFR 1910.180(d)(3)(iii): Frequesnt Inspections were not conducted to identify whether safety devices were fully functioning.       a) Dry dock; On or about 9/05/13, an employee was allowed to operate a Manitowoc 3900 crane without having the moving parts such as but not limited to the engine fully enclosed to prevent inadvertent contact.
Recent events (2)
  • — I (S) $1050
  • — Z (S) $3500

1910.180 C02

Serious Gravity 10 4 instances 20 exposed
Issued
Oct 17, 2013
Abate by
Oct 31, 2013
Penalty
Initial $4,900 · Current $2,450 Reduced
29 CFR 1910.180(c)(2): The cab(s) of crawler crane(s) were not provided with a load rating chart with clearly legible letters and figures which was easily visible to the operator while seated at the control station:   a) Dry dock; employees were allowed to operate cranes without having a load rating chart available to the operator.      1. American 9225 crane      2. American 9310 crane      3. Manitowoc 3900 crane      4. Manitowoc 4600 crane
Recent events (2)
  • — I (S) $2450
  • — Z (S) $4900

1910.180 D04

Serious Gravity 10 5 instances 3 exposed
Issued
Oct 17, 2013
Abate by
Dec 5, 2013
Penalty
Initial $4,900 · Current $0 Reduced
29 CFR 1910.180(d)(4): Complete inspection(s) of crane(s) were not performed at intervals as generally defined in 1910.180(d)(ii) with a determination made as to whether deficiencies constituted a safety hazard:      a) Dry dock; On or about 9/05/13, the employer allowed employees to operate cranes while not having a current annual inspection or periodic inspections performed.        1. American 9225 crane        2. American 9310 crane        3. Manitowoc 3900 crane        4. Manitowoc 4600 crane
Recent events (2)
  • — I (S) $0
  • — Z (S) $4900

1910.212 A03 II

Deleted Serious Gravity 1 1 instance 4 exposed
Issued
Oct 17, 2013
Abate by
Nov 12, 2013
Penalty
Initial $2,100 · Current $0 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):   a) Bay 6; a Central Machinery Drill Press did not have a guard around the bit to prevent a point of operation injury.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2100

1910.305 B02 I

Serious Gravity 1 3 instances 16 exposed
Issued
Oct 17, 2013
Abate by
Oct 31, 2013
Penalty
Initial $2,100 · Current $1,050 Reduced
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:   a) Bay 3; Two electrical boxes connected to the overhead doors were missing covers.  b) Bay 5; Electrical box connected to bay door was missing cover.
Recent events (2)
  • — I (S) $1050
  • — Z (S) $2100

1910.306 K02 VI

Deleted Serious Gravity 1 1 instance 4 exposed
Issued
Oct 17, 2013
Abate by
Oct 29, 2013
Penalty
Initial $2,100 · Current $0 Reduced
29 CFR 1910.306(k)(2)(vi): Flexible cords and cables shall be continuous without splice or tap between boxes or fittings. Cord connectors may not be laid on the ground unless listed for wet locations. Connectors and cable connections may not be placed in audience traffic paths or within areas accessible to the public unless guarded.   a) Bay 7; On or about 9/5/13, the electrical cord of a fan was spliced without providing an insulating device equivalent to that of the conductors or otherwise designed for the purpose.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2100

1915.89 D01

Serious Gravity 5 4 instances 12 exposed
Issued
Oct 17, 2013
Abate by
Dec 5, 2013
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1915.89(d)(1): The employer shall establish and implement written procedures to prevent energization or startup, or the release of hazardous energy, during the servicing of any machinery, equipment, or system.    a) Bay 1; the employer did not develop written procedures with specific steps for the control of potentially hazardous energy regarding machines and equipment such as, but not limited to:         1. Band Saw - electrical and pneumatic energy sources       2. Two Plasma Cutters - electrical and pneumatic energy sources          3. Seam Welder - electrical, hydraulic, and pneumatic energy sources      4. Dart Welder - electrical and pneumatic energy sources
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1915.134 F

Serious Gravity 5 3 instances 6 exposed
Issued
Oct 17, 2013
Abate by
Oct 31, 2013
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1915.134(f): When safety flanges are required, they shall be used only with wheels designed to fit the flanges. Only safety flanges of a type and design and properly assembled so as to insure that the pieces of the wheel will be retained in case of accidental breakage shall be used.   a) Bay 5; On or about 9/05/13, the employer allowed employees to operate Dewalt side grinders while missing the guard.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3500

1910.180 I05 I

Other-than-serious 4 instances 3 exposed
Issued
Oct 17, 2013
Abate by
Oct 31, 2013
Penalty
Initial $700 · Current $350 Reduced
29 CFR 1910.180(i)(5)(i): A carbon dioxide, dry chemical, or equivalent fire extinguisher was not kept in the cab or the vicinity of the locomotive crane(s):   a) Dry dock; On or about 9/5/13, employees were allowed to operate cranes without having a 5-BC rating or equivalent fire extinguisher accessible in the cab of the crane.       1. American 9225 crane      2. American 9310 crane      3. Manitowoc 3900 crane      4. Manitowoc 4600 crane
Recent events (2)
  • — I (O) $350
  • — Z (O) $700

1910.303 F02

Other-than-serious 1 instance 8 exposed
Issued
Oct 17, 2013
Abate by
Oct 31, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:    a) Bay 3; The employer failed to ensure that the individual breakers inside of electrical panel PLC feed from MDPC were labeled.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View C & C Marine and Repair, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339396079.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.