VERO BEACH, FL —
OSHA Inspection: BRIAN DAVIS SEPTIC & BACKHOE SERVICES, INC
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of BRIAN DAVIS SEPTIC & BACKHOE SERVICES, INC in 1325 74TH AVENUE SW, VERO BEACH, FL 32968 (NAICS 562991). OSHA activity number 339398232.
Where did this inspection happen?
- Establishment
- BRIAN DAVIS SEPTIC & BACKHOE SERVICES, INC
- Site address
- 1325 74TH AVENUE SW
- City
- VERO BEACH
- State
- FL
- ZIP
- 32968
- Mailing
- 7200 84TH AVE, VERO BEACH, FL 32967
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 562991
- Employees
- 10
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.146 C01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces: On or about September 6. 2013, the employer had not evaluated the tanks that transport spetic tank sewage.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1910.146 C02
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1910.146(c)(2): The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces: On or about Semtember 6, 2013, the employer had not posted Permit Required Confined Space, Do Not Enter signs on the tanks used to transport sewage.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1910.146 G01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1910.146(g)(1): The employer did not provide training so that all employees whose work was regulated by 29 CFR 1910.146 (permit required confined spaces) acquired the understanding, knowledge, and skills necessary for the safe performance of the duties assigned under 29 CFR 1910.146:(a) (LOCATION) (SPECIFIC OPERATIONS AND/OR CONDITIONS) On or about September 6, 2013, the employer had not provided "no entry" training to the employees who transport septic sewage in tanks the have hatches large enough to alllow entry.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
More inspections in this industry (NAICS 562991)
SUNNYSIDE, WA—2026-04-28
WA317991004 - CENTENNIAL TANK CLEANING INC
MOUNT HOLLY, NJ—2026-04-27
ERIC TOWN ENTERPRISES
HAVERHILL, MA—2026-04-10
J AND S DEVELOPMENT CORPORATION
NORTH BRANCH, MN—2026-04-09
111031 - LAKESHORE RECYCLING SYSTEMS LLC
SHEPHERDSVILLE, KY—2026-03-20
68966 - A1 SEWER AND DRAIN LLC
More inspections in FL
MARIANNA, FL—2026-07-13
PRIMETIME MOBILE MASONRY LLC
MELBOURNE, FL—2026-07-13
OMNIPOTENT BRANDS, LLC
QUINCY, FL—2026-07-13
WALMART
INDIAN ROCKS BEACH, FL—2026-07-10
UNKNOWN CONTRACTOR
CLEARWATER, FL—2026-07-10
ROOFTECH ROOFING & WATERPROOFING INC