Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JAX UTILITIES MANAGEMENT, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JAX UTILITIES MANAGEMENT, INC. in 3815 MIRUELO CIRCLE N., JACKSONVILLE, FL 32257 (NAICS 237110). OSHA activity number 339405698.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch JAX Utilities Management, INC. — free Get an email when a new federal OSHA severe-injury report for JAX Utilities Management, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3815 MIRUELO CIRCLE N.
City
JACKSONVILLE
State
FL
ZIP
32257
Mailing
5465 VERNA BLVD, JACKSONVILLE, FL 32205
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
6
Ownership type
A

5 citations on file for this inspection.

1926.600 A06 I

Serious Gravity 10 1 instance 3 exposed
Issued
Sep 24, 2013
Penalty
Initial $4,900 · Current $1,634 Reduced
29 CFR 1926.600(a)(6)(i):  For lines rated 50kV or below, a minimum of 10 feet was not maintained between the energized line and the equipment:  a.  On or about September 5, 2013, an employee was operating an excavator approximately 7 feet from high voltage electrical power lines while digging an excavation, exposing employees to an electrical hazard.
Recent events (2)
  • — I (S) $1634
  • — Z (S) $4900

1926.651 I03

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 24, 2013
Penalty
Initial $4,900 · Current $1,633 Reduced
29 CFR 1926.651(i)(3): Sidewalks, pavements, or appurtenant structures had been undermined and a support system or another method was not provided to protect employees from the possible collapse of such structures:  a.  On or about September 5, 2013, an employee operating an excavator undermined the asphalt pavement while conducting trench and excavation operations, exposing employees to cave-in hazards.
Recent events (2)
  • — I (S) $1633
  • — Z (S) $4900

1926.651 J02

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 24, 2013
Penalty
Initial $4,200 · Current $1,633 Reduced
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary:  a.  On or about September 5, 2013, an employee operating an excavator placed the spoils directly on the edge of the excavation, exposing employees to the hazard of large chunks of soil and other debris rolling back into the excavation.
Recent events (2)
  • — I (S) $1633
  • — Z (S) $4200

1926.652 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 24, 2013
Penalty
Initial $7,000 · Current $7,000
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c):  a.  On or about September 5, 2013, in the 8 feet 5-inch deep excavation, employees were not protected from cave-ins by the use of a trench box, shoring, or sloping, exposing employees to cave-in hazards.
Recent events (2)
  • — I (S) $7000
  • — Z (S) $7000

1926.1053 B16

Other-than-serious 1 instance 2 exposed
Issued
Sep 24, 2013
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired:    a.  On or about September 5, 2013, employees were using a 20-foot defective fiberglass extension ladder for egress and access while conducting trenching and excavation operations.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2800

View JAX Utilities Management, INC.'s full OSHA safety record →