JACKSONVILLE, FL —
OSHA Inspection: JAX UTILITIES MANAGEMENT, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JAX UTILITIES MANAGEMENT, INC. in 3815 MIRUELO CIRCLE N., JACKSONVILLE, FL 32257 (NAICS 237110). OSHA activity number 339405698.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JAX UTILITIES MANAGEMENT, INC.
- Site address
- 3815 MIRUELO CIRCLE N.
- City
- JACKSONVILLE
- State
- FL
- ZIP
- 32257
- Mailing
- 5465 VERNA BLVD, JACKSONVILLE, FL 32205
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 6
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.600 A06 I
- Issued
- Sep 24, 2013
- Penalty
- Initial $4,900 · Current $1,634 Reduced
General-duty citation text
29 CFR 1926.600(a)(6)(i): For lines rated 50kV or below, a minimum of 10 feet was not maintained between the energized line and the equipment: a. On or about September 5, 2013, an employee was operating an excavator approximately 7 feet from high voltage electrical power lines while digging an excavation, exposing employees to an electrical hazard.
Recent events (2)
- — I (S) $1634
- — Z (S) $4900
1926.651 I03
- Issued
- Sep 24, 2013
- Penalty
- Initial $4,900 · Current $1,633 Reduced
General-duty citation text
29 CFR 1926.651(i)(3): Sidewalks, pavements, or appurtenant structures had been undermined and a support system or another method was not provided to protect employees from the possible collapse of such structures: a. On or about September 5, 2013, an employee operating an excavator undermined the asphalt pavement while conducting trench and excavation operations, exposing employees to cave-in hazards.
Recent events (2)
- — I (S) $1633
- — Z (S) $4900
1926.651 J02
- Issued
- Sep 24, 2013
- Penalty
- Initial $4,200 · Current $1,633 Reduced
General-duty citation text
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary: a. On or about September 5, 2013, an employee operating an excavator placed the spoils directly on the edge of the excavation, exposing employees to the hazard of large chunks of soil and other debris rolling back into the excavation.
Recent events (2)
- — I (S) $1633
- — Z (S) $4200
1926.652 A01
- Issued
- Sep 24, 2013
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c): a. On or about September 5, 2013, in the 8 feet 5-inch deep excavation, employees were not protected from cave-ins by the use of a trench box, shoring, or sloping, exposing employees to cave-in hazards.
Recent events (2)
- — I (S) $7000
- — Z (S) $7000
1926.1053 B16
- Issued
- Sep 24, 2013
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired: a. On or about September 5, 2013, employees were using a 20-foot defective fiberglass extension ladder for egress and access while conducting trenching and excavation operations.
Recent events (2)
- — I (O) $0
- — Z (S) $2800
More inspections at JAX Utilities Management, INC.
View JAX Utilities Management, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 237110)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339405698.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.